Accuracy of tropospheric and stratospheric water vapor measurements by the cryogenic frost point hygrometer: Instrumental details and observations

نویسندگان

  • H. Vömel
  • D. E. David
  • K. Smith
چکیده

[1] The cryogenic frost point hygrometer (CFH), currently built at the University of Colorado, is a new balloon borne hygrometer, which is capable of continuously measuring water vapor between the surface and the middle stratosphere. The design is loosely based on the old NOAA/CMDL frost point hygrometer, with improved accuracy and a number of significant new features that overcome some limitations of the older instrument. The measurement uncertainty of the new instrument depends on altitude and ranges between less than 4% in the tropical lower troposphere to no more than 10% in the middle stratosphere at 28 km. In the tropopause region the uncertainty is less than 9%. This instrument is used routinely at several sites for validation of satellite measurements and process studies in the upper troposphere and lower stratosphere region. It has proved to be particularly well suited for dehydration observations in the tropical upper troposphere, because the effects of cloud contamination have been significantly reduced. Results of this instrument are compared with the old NOAA/CMDL hygrometer, the Russian Fluorescent Lyman Alpha Stratospheric Hygrometer, the Vaisala RS92, the AURA/MLS satellite instrument, a cloud lidar, the NOAA/CSD frost point hygrometer and the Harvard Lyman-alpha hygrometer, both of the later instruments flown on board the NASAWB-57F high-altitude research aircraft. These comparisons demonstrate the level of accuracy of tropospheric and stratospheric water vapor measurements made by this instrument and point to areas where more research and development are needed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Advancements, measurement uncertainties, and recent comparisons of the NOAA frost point hygrometer

The NOAA frost point hygrometer (FPH) is a balloon-borne instrument flown monthly at three sites to measure water vapor profiles up to 28 km. The FPH record from Boulder, Colorado, is the longest continuous stratospheric water vapor record. The instrument has an uncertainty in the stratosphere that is < 6 % and up to 12 % in the troposphere. A digital microcontroller version of the instrument i...

متن کامل

Observationally derived and general circulation model simulated tropical stratospheric upward mass fluxes

[1] We quantify the vertical velocity and upward mass flux in the tropical lower stratosphere on the basis of accurate radiative heating rate calculations using 8-year Southern Hemisphere Additional Ozonesondes balloon-borne measurements of temperature and ozone and cryogenic frost-point hygrometer measured water vapor in the tropics (15 S—10 N). The impact of tropospheric clouds on the stratos...

متن کامل

Validation of the Harvard Lyman-a in situ water vapor instrument: Implications for the mechanisms that control stratospheric water vapor

[1] Building on previously published details of the laboratory calibrations of the Harvard Lyman-a photofragment fluorescence hygrometer (HWV) on the NASA ER-2 and WB-57 aircraft, we describe here the validation process for HWV, which includes laboratory calibrations and intercomparisons with other Harvard water vapor instruments at water vapor mixing ratios from 0 to 10 ppmv, followed by in-fl...

متن کامل

Estimation and Analysis of Precipitable Water Vapor Using GPS Data and Satellite Altimeter

Determination of water vapor in the atmosphere plays an important role in forecasting weather conditions and precipitation studies. For this reason, it is very important to study the tropospheric delay, especially the wet component, which is due to the presence of water vapor in the atmosphere. In this paper, the amount of water vapor was estimated by altimeter satellite radiometer and GPS data...

متن کامل

Accuracy assessment and correction of Vaisala RS92 radiosonde water vapor measurements

[1] Relative humidity (RH) measurements from Vaisala RS92 radiosondes are widely used in research and operational applications, but their accuracy is not well characterized as a function of height, RH, and time of day (or solar altitude angle). This study compares RS92 RH measurements to simultaneous water vapor measurements from three reference instruments of known accuracy. Cryogenic frost po...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007