The wing stent facilitates repeat bile duct cannulation for multiple stent insertion.

نویسندگان

  • M A Khashab
  • V K Singh
  • A M Lennon
  • S A Giday
چکیده

plastic biliary stents is their short patency rate [1], as they are prone to biofilm buildup within the central lumen of the stent, resulting in impaired bile flow [2]. The wing stent (ViaDuct; GI Supply, Camp Hill, Pennsylvania, USA) was engineered to overcome this problem (●" Fig. 1). The wing stent is a lumenless stent in which bile is channeled along the exterior winged grooves, theoretically reducing the risk of occlusion (●" Fig. 1) [3,4]. Computer modeling studies have shown that the wing stent offers a larger surface area for flow, a higher flow velocity, and increased flow rates compared with conventional plastic stents. A pilot study reported the successful use of thewing stent for endoscopic biliary drainage in five patients with malignant biliary obstruction, all of whom experienced a significant decline in bilirubin at 2 weeks and resolution of biliary dilation by radiologic imaging [3]. The endoscopic placement of multiple stents over time for patients with benign biliary strictures has been shown to be an effective therapy for stricture resolution [5]. The placement of multiple stents can be technically challenging for a number of reasons, including failure of repeat biliary cannulation after the first stent insertion. This can occur if a small biliary sphincterotomy was performed and/or the positioning of the first stent prevents the necessary angulation of the biliary cannula or sphincterotome. This problem can be overcome by initially placing a 7Fr or 10-Fr wing stent into position using a push catheter until the radiopaque black marker at the distal end of the stent is visualized at the biliary orifice. Subsequently, rapid repeat biliary cannulation is achieved by advancing a guidewire into the groove between two wings of the insitu wing stent and into the proximal bile duct. A conventional plastic stent is then placed over the wire and advanced into the bile duct. Additional stents can then be placed in similar manner (●" Fig. 2, ●" Video 1).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Successful outcome of sphincterotomy and 7 French pigtail stent insertion in the management of post-cholecystectomy bile leaks.

BACKGROUND Endoscopic retrograde cholangiopancreatography (ERCP) is widely used to manage post-cholecystectomy bile leaks. However, the best endoscopic intervention remains controversial. We investigated the success of a 7 French double pigtail stent following sphincterotomy in the management of such bile leaks. METHODS Between July 1998 and June 2008, 48 patients were referred for ERCP for p...

متن کامل

Guidewire stent cannulation and sphincterotome-assisted extraction of proximally migrated biliary plastic stent.

assisted extraction of proximally migrated biliary plastic stent Stent placement is widely indicated as treatment for biliary obstruction or compression [1]. However, migration is frequently observed, particularly when plastic stents are used for benign strictures. Distally migrated stents are usually spontaneously eliminated and do not require any intervention. Proximal migration often require...

متن کامل

Endoscopic bilateral stenting of malignant hilar bile duct obstruction using novel partially covered self-expandable metal stents.

Endoscopic bilateral stenting using conventional metal stents is considered to be technically difficult in patients with malignant hilar bile duct obstruction because the second stent is not easily inserted through the cell of the first stent wall in the bile duct [1]. A variety of new self-expandable metal stents (SEMS) specially designed for stent-in-stent procedures to facilitate bilateral s...

متن کامل

Use of a Soehendra stent retriever in dilation of an anastomotic biliary stricture in a post-liver transplant patient.

Occasionally, bile duct strictures in patients who have undergone liver transplantation are impossible to traverse, dilate, and stent. Herein we present a novel technique for the dilation of a recalcitrant stricture using the Soehendra stent retriever device. A 57-year-old woman with a history of orthotopic liver transplantation presented to the emergency department with pruritus and right-uppe...

متن کامل

The outcome of endoscopic management of bile leakage after hepatobiliary surgery

BACKGROUND/AIMS Despite improvements in surgical techniques and postoperative patient care, bile leakage can occur after hepatobiliary surgery and may lead to serious complications. The aim of this retrospective study was to evaluate the efficacy of endoscopic treatment of bile leakage after hepatobiliary surgery. METHODS The medical records of 20 patients who underwent endoscopic retrograde ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Endoscopy

دوره 42 Suppl 2  شماره 

صفحات  -

تاریخ انتشار 2010