Carrier mobility for organic semiconductors: reduction of noise of the short part drift time in the time of flight mobility method.
نویسندگان
چکیده
Measurements of time of flight (TOF) mobility of organic semiconductors become difficult when the mobility values are high, since the electronic signals overlap with the noise of the short part in drift time. Such noise of the short part in the drift time in the TOF method for measurements of carrier mobility was reduced by three methods: (1) longer distance (3.5 m) between sample and the N(2) laser, (2) optical connection (photo coupler) between the N(2) laser and the pulse generator, and (3) using a digital filter to remove characteristic pulses caused by N(2) laser. Each method showed significant reduction of the noise. When all three methods were applied, 94% of the noise was reduced. The measurement of TOF mobility was demonstrated with TPD (N,N'-diphenyl-N,N'-di(meta-tolyl)benzidine) film. Electronic signals in TOF measurements were clearly observed and the TOF mobility was determined to be 9.0 x 10(-4) cm(2)/V s.
منابع مشابه
Field Dependent Charge Carrier Transport for Organic Semiconductors at the Time of Flight Configuration
In this paper, we used the time-of-flight (TOF) of a charge packet, that injected by a voltage pulse to calculate the drift velocity and mobility of holes in organic semiconducting polymers. The technique consists in applying a voltage to the anode and calculating the time delay in the appearance of the injected carriers at the other contact. The method is a simple way to determine the charge t...
متن کاملScattering mechanism of nonmagnetic phase on nano diluted magnetic semiconductors (DMS)
This paper shows the scattering mechanism at diluted magneticsemiconductors. The doped magnetic atom produces a scattering potential due to becoupled of itinerant carrier spin of host material with magnetic momentum of the dopedmagnetic atom. Formulas of scattering event were rewritten by the plane waveexpansion and then the electron mobility of DMS was calculated. Calculations showKondo effect...
متن کاملApplication of Ion Mobility Spectrometry for Determination of Morphine in Human Urine
In this study, a rapid, simple and sensitive ion mobility spectrometry (IMS) method with corona discharge as ionization source was described for the morphine determination in human urine. Morphine was extracted and purified from urine samples using solid phase extraction procedure with C18 column. It can offer the clean extracts which no extra peaks were observed in IMS. Under operating experim...
متن کاملDETECTION AND MEASUREMENT OF ACETONE IN THE BREATH OF DIABETICS BY ION MOBILITY SPECTROMETRY METHOD
Background: The ion mobility spectrometry (IMS) is an analytical technique that is widely used due to its high sensitivity and speed for the detection of ionized molecules in gas phase and under atmospheric pressure. Breath analysis is a new method for obtaining information about person's clinical conditions that is considered by researchers. Human exhaled air contains a variety of components s...
متن کاملA novel calamitic mesophase semiconductor with the fastest mobility of charged carriers: 1,4-di(5'-octyl-2'-thienyl)benzene.
The carrier mobility of highly ordered lamellar mesophases was evaluated by a Time-of-Flight (TOF) method for mesogenic 1,4-di(5'-octyl-2'-thienyl)benzene (8-TPT-8) to reveal the fastest drift mobility (0.1 cm(2) V(-1) s(-1) for the lowest temperature mesophase) in calamitic liquid crystals reported to date.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 23 10 شماره
صفحات -
تاریخ انتشار 2007