Simultaneous PIV and PTV measurements of wind and sand particle velocities
نویسندگان
چکیده
Wind-blown sand is a typical example of twophase particle-laden flows. Owing to lack of simultaneous measured data of the wind and wind-blown sand, interactions between them have not yet been fully understood. In this study, natural sand of 100–125 lm taken from Taklimakan Desert was tested at the freestream wind speed of 8.3 m/s in an atmospheric boundary layer wind tunnel. The captured flow images containing both saltating sand and small wind tracer particles, were separated by using a digital phase mask technique. The 2-D PIV (particle imaging velocimetry) and PTV (particle tracking velocimetry) techniques were employed to extract simultaneously the wind velocity field and the velocity field of dispersed sand particles, respectively. Comparison of the mean streamwise wind velocity profile and the turbulence statistics with and without sand transportation reveal a significant influence of sand movement on the wind field, especially in the dense saltating sand layer (y/ d\ 0.1). The ensemble-averaged streamwise velocity profile of sand particles was also evaluated to investigate the velocity lag between the sand and the wind. This study would be helpful in improving the understanding of interactions between the wind and the wind-blown sand.
منابع مشابه
Particle Image Velocimetry (PIV) for Granular Avalanches on Inclined Planes
This paper is concerned with experimental results of sand avalanches flowing down inclined plexiglass chutes with lateral confinement. Specifically we introduce the particle image velocimetry (PIV) technique for granular avalanches. We discuss the differences and problems in comparison with “usual” PIV. After this, we present surface and side velocity measurements that are obtained at different...
متن کاملSimultaneous velocity and concentration measurements of a turbulent jet mixing flow.
A method for the simultaneous measurement of velocity and passive scalar concentration fields by means of particle image velocimetry (PIV) and planar laser induced florescence (PLIF) techniques is described here. An application of the combined PIV-PLIF system is demonstrated by performing simultaneous velocity and concentration measurements in the near field of a turbulent jet mixing flow. The ...
متن کاملSimultaneous measurements with 3D PIV and Acoustic Doppler Velocity Profiler
Simultaneous velocity measurements were taken using Particle Image Velocimetry (PIV) and an Acoustic Doppler Velocity Profiler (ADVP) in a sharp open-channel bend with an immobile gravel bed. The PIV measures 3D velocity vectors in a vertical plane (~40cm x 20cm) at a frequency of 7.5 Hz, whereas the ADVP measures 3D velocity vectors in a vertical profile with a frequency of 31.25 Hz. The paper...
متن کاملHeat Transfer Enhancement of a Flat Plate Boundary Layer Distributed by a Square Cylinder: Particle Image Velocimetry and Temperature-Sensitive Paint Measurements and Proper Orthogonal Decomposition Analysis
The current empirical study was conducted to investigate the wall neighborhood impact on the two-dimensional flow structure and heat transfer enhancement behind a square cylinder. The low- velocity open-circle wind tunnel was used to carry out the study tests considering the cylinder diameter (D)-based Reynolds number (ReD) of 5130. The selected items to compare were different gap he...
متن کاملParticle tracking techniques for electrokinetic microchannel flows.
We have applied particle tracking techniques to obtain spatially resolved velocity measurements in electrokinetic flow devices. Both micrometer-resolution particle image velocimetry (micro-PMV) and particle tracking velocimetry (PTV) techniques have been used to quantify and study flow phenomena in electrokinetic systems applicable to microfluidic bioanalytical devices. To make the flow measure...