Cutoff probe using Fourier analysis for electron density measurement.

نویسندگان

  • Byung-Keun Na
  • Kwang-Ho You
  • Dae-Woong Kim
  • Hong-Young Chang
  • Shin-Jae You
  • Jung-Hyung Kim
چکیده

This paper proposes a new method for cutoff probe using a nanosecond impulse generator and an oscilloscope, instead of a network analyzer. The nanosecond impulse generator supplies a radiating signal of broadband frequency spectrum simultaneously without frequency sweeping, while frequency sweeping method is used by a network analyzer in a previous method. The transmission spectrum (S21) was obtained through a Fourier analysis of the transmitted impulse signal detected by the oscilloscope and was used to measure the electron density. The results showed that the transmission frequency spectrum and the electron density obtained with a new method are very close to those obtained with a previous method using a network analyzer. And also, only 15 ns long signal was necessary for spectrum reconstruction. These results were also compared to the Langmuir probe's measurements with satisfactory results. This method is expected to provide not only fast measurement of absolute electron density, but also function in other diagnostic situations where a network analyzer would be used (a hairpin probe and an impedance probe) by replacing the network analyzer with a nanosecond impulse generator and an oscilloscope.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

First mesospheric in-situ measurement in Iran using sounding rockets and plasma impedance probe (PIP)

This paper reports on the progress for the first development of rocket probe for in-situ measurement of ionospheric plasma parameters in Iran. The designed probe known as Plasma Impedance Probe (PIP) will be used to measure the electron density, electron-neutral collision frequency, background magnetic field, and temperature in the mesospheric and in the altitude range of 70 km to 150 km. This ...

متن کامل

Double Langmuir probe measurement of plasma parameters in a dc glow discharge

In this paper, plasma main characteristics such as electron mean temperature, electron number density, and oscillation frequency have been measured experimentally using the double Langmuir probe diagnostic system. In our experiment, the plasma was generated by applying the low pressure dc glow discharge in several common gases. The experimental results indicated the highest plasma density and o...

متن کامل

Measurement of Plain Weave Fabrics Density Using Fourier Transforms

Warp and weft spacing and its coefficient of variation affect the physical properties of fabrics such as fabric hand, frictional and mechanical properties. In this paper the weft and warp spacing and its coefficient of variation for plain weave is calculated using Fourier transforms. Different methods have been used in this work including autocorrelation function. First, two dimensional power s...

متن کامل

Measurement of Plain Weave Fabrics Density Using Fourier Transforms

Warp and weft spacing and its coefficient of variation affect the physical properties of fabrics such as fabric hand, frictional and mechanical properties. In this paper the weft and warp spacing and its coefficient of variation for plain weave is calculated using Fourier transforms. Different methods have been used in this work including autocorrelation function. First, two dimensional power s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 83 1  شماره 

صفحات  -

تاریخ انتشار 2012