Effects of intermittent negative pressure ventilation on effective ventilation in normal awake subjects.
نویسندگان
چکیده
RATIONALE Previous studies have shown that an increase in inspiratory pressure during nasal intermittent positive pressure ventilation (IPPV) does not result in increased effective minute ventilation (E) due to glottic interference. STUDY OBJECTIVES To test the consequences of increases in negative pressure ventilation (NPV) on V(E). MATERIAL AND METHODS Eight healthy awake subjects underwent NPV delivered by an iron lung. First, NPV was started at a respirator frequency (f) of 15 cycles per minute with an inspiratory negative pressure (INP) of - 15 cm H(2)O (F15-P15). Then, f was increased to 20 cycles per minute and INP was kept at - 15 cm H(2)O. Next, f was kept at 20 cycles per minute and INP was reduced to - 30 cm H(2)O (F20-P30). Finally, f was decreased to 15 cycles per minute and INP was kept at - 30 cm H(2)O. At each step and for each breath, effective tidal volume (VT), V(E), and end-tidal carbon dioxide pressure were measured. In three subjects, the glottis width was assessed using fiberoptic bronchoscopy. RESULTS From spontaneous breathing to the first step of NPV (F15-P15), we observed an inhibition of the phasic inspiratory diaphragmatic electromyogram concomitant to a significant increase in V(E) (p < 0.0005). For the group as a whole, the increase in mechanical ventilation (from F15-P15 to F20-P30) resulted in significant increases in VT and V(E) leading to hypocapnia (p < 0.0005). Moreover, the glottis width did not decrease with the increase in mechanical ventilation. CONCLUSIONS We conclude that in normal awake subjects, NPV allowed a significant increase in V(E). These results differ from those previously obtained with nasal IPPV in which the glottic width interferes with the delivered mechanical ventilation.
منابع مشابه
Determinants of effective ventilation during nasal intermittent positive pressure ventilation.
Our aim was to verify in healthy subjects submitted to nasal intermittent positive pressure ventilation (nIPPV) with a volumetric ventilator on controlled mode, whether changes in ventilator settings (delivered tidal volume (VT), respiratory frequency (fR) and inspiratory flow (V'I) could influence effective minute ventilation (V'E), thus allowing identification of the settings resulting in the...
متن کاملA Comparison between Nasal Intermittent Positive Pressure Ventilation and Nasal Continuous Positive Airway Pressure Ventilation in the Treatment of Neonatal Respiratory Distress Syndrome
Background: Nasal intermittent positive pressure ventilation (NIPPV) is a non-invasive ventilatory mode, which delivers mechanical ventilation via nasal tubes or prongs. The present study was conducted to compare the efficacy of NIPPV and nasal continuous positive airway pressure ventilation (NCPAP) in reducing the need for intubation in preterm infants with respiratory distress syndrome (RDS)....
متن کاملAdaptation to intermittent positive pressure ventilation applied through the nose during day and night.
A 49 yr old poliomyelitic patient had been under cuirass-type nocturnal negative pressure ventilation for more than 20 yrs. He had a severe restrictive ventilatory impairment, and normal awake blood gases at rest and during light exercise. He was offered a trial of intermittent positive pressure ventilation applied through the nose (nIPPV). Two daytime studies and one night study were carried o...
متن کاملComparison of Nasal Non-invasive Ventilation Methods in Preterm Neonates with Respiratory Distress Syndrome
Background: Humidified heated high flow nasal cannula (HHHFNC), nasal continuous positive airway pressure (NCPAP), and nasal intermittent positive pressure ventilation (NIPPV) are three nasal non-invasive ventilation methods. The purpose of this study was to compare these three methods in decreasing intubation and mechanical ventilation rate in preterm neonates with respiratory distress syndrom...
متن کاملEffectiveness of Nasal Intermittent Positive Pressure Ventilation versus Nasal Continuous Positive Airway Pressure in Preterm Infants after Less Invasive Surfactant Administration
Background Non-invasive ventilation is increased used in preterm infants. We aimed to compare the effectiveness of nasal intermittent positive pressure ventilation (nIPPV) versus nasal continuous positive airway pressure (nCPAP) in preterm infants with respiratory distress syndrome (RDS) after less invasive surfactant administration (LISA). Materials and Methods In this clinical trial, eighty ...