Laser diode thermal desorption atmospheric pressure chemical ionization tandem mass spectrometry applied for the ultra-fast quantitative analysis of BKM120 in human plasma.

نویسندگان

  • Christian Lanshoeft
  • Olivier Heudi
  • Luc Alexis Leuthold
  • Götz Schlotterbeck
  • Walid Elbast
  • Franck Picard
  • Olivier Kretz
چکیده

A sensitive and ultra-fast method utilizing the laser diode thermal desorption ion source using atmospheric pressure chemical ionization coupled to tandem mass spectrometry (LDTD-APCI-MS/MS) was developed for the quantitative analysis of BKM120, an investigational anticancer drug in human plasma. Samples originating from protein precipitation (PP) followed by salting-out assisted liquid-liquid extraction (SALLE) were spotted onto the LazWell™ plate prior to their thermal desorption and detection by tandem mass spectrometry in positive mode. The validated method described in this paper presents a high absolute extraction recovery (>90 %) for BKM120 and its internal standard (ISTD) [D8]BKM120, with precision and accuracy meeting the acceptance criteria. Standard curves were linear over the range of 5.00 to 2000 ng mL(-1) with a coefficient of determination (R (2)) >0.995. The method specificity was demonstrated in six different batches of human plasma. Intra- and inter-run precision as well as accuracy within ±20 % at the lower limit of quantification (LLOQ) and ±15 % (other levels) were achieved during a three-run validation for quality control (QC) samples. The post-preparative stability on the LazWell™ plate at room temperature was 72 h and a 200-fold dilution of spiked samples was demonstrated. The method was applied successfully to three clinical studies (n = 847) and cross-checked with the validated LC-ESI-MS/MS reference method. The sample analysis run time was 10 s as compared to 4.5 min for the current validated LC-ESI-MS/MS method. The resultant data were in agreement with the results obtained using the validated reference LC-ESI-MS/MS assay and the same pharmacokinetic (PK) parameters were calculated for both analytical assays. This work demonstrates that LDTD-APCI-MS/MS is a reliable method for the ultra-fast quantitative analysis of BKM120 which can be used to speed-up and support its bioanalysis in the frame of the clinical trials.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of metformin in mouse, rat, dog and human plasma samples by laser diode thermal desorption/atmospheric pressure chemical ionization tandem mass spectrometry.

A simple, rapid and robust high-throughput assay for the quantitative analysis of metformin in plasma from different species using laser diode thermal desorption interfaced with atmospheric chemical pressure ionization tandem mass spectrometry (LDTD-APCI-MSMS) was developed for use in a pharmaceutical discovery environment. In order to minimize sample preparation a generic protein precipitation...

متن کامل

Laser diode thermal desorption/atmospheric pressure chemical ionization tandem mass spectrometry analysis of selected steroid hormones in wastewater: method optimization and application.

A rapid and reliable method enabling high-throughput sample analysis for quicker data generation, detection, and monitoring of eight selected steroid hormones in water matrixes was developed and validated. Our approach is based on a novel sample introduction method, the laser diode thermal desorption/atmospheric pressure chemical ionization (LDTD/APCI) coupled to tandem mass spectrometry (MS/MS...

متن کامل

Using a novel sol-gel stir bar sorptive extraction method for the analysis of steroid hormones in water by laser diode thermal desorption/atmospheric chemical ionization tandem mass spectrometry.

A new coating material was used for a stir bar sorptive extraction (SBSE) method coupled to a high throughput sample analysis technique. This allowed for a simple procedure for fast determinations of eight steroid hormones (estriol, estradiol, ethynylestradiol, estrone, progesterone, medroxyprogesterone, levonorgestrel, northindrone) in water. Sample pre-treatment was performed using an in-hous...

متن کامل

Solid Sampling with a Diode Laser for Portable Ambient Mass Spectrometry

A hand-held diode laser is implemented for solid sampling in portable ambient mass spectrometry (MS). Specifically, a pseudocontinuous wave battery-powered surgical laser diode is employed for portable laser diode thermal desorption (LDTD) at 940 nm and compared with nanosecond pulsed laser ablation at 2940 nm. Postionization is achieved in both cases using atmospheric pressure photoionization ...

متن کامل

Droplet-based electrospray ionization mass spectrometry for qualitative and quantitative analysis.

Mass spectrometry (MS) is a rapid and sensitive analytical tool that can provide information such as molecular weight and structure. One of the fast growing fields in MS in the beginning of this century is the development of ion sources at atmospheric pressure. Speed, simplicity and minimal sample preparation are the main characteristics of these recently developed ion sources at open air. Most...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical and bioanalytical chemistry

دوره 406 22  شماره 

صفحات  -

تاریخ انتشار 2014