Thrombocytopenia in the Setting of Hemodialysis Using Biocompatible Membranes

نویسندگان

  • Kathryn B. Muir
  • Clifford D. Packer
چکیده

Thrombocytopenia is a known potential side effect of hemodialysis, however, it is rarely seen in patients who undergo hemodialysis using biocompatible membranes. This case demonstrates hemodialysis-associated thrombocytopenia with use of biocompatible dialysis membranes that expose blood directly to polysulfone. The thrombocytopenia resolved in this patient when the dialysis membrane was changed to a biocompatible model with a polyethylene glycol barrier layer preventing direct interaction between patient blood and polysulfone. The calculated Naranjo ADR score of 9 indicates a highly probable adverse reaction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative analysis of the long-term effect of two families of high-flux polysulfone dialysers on platelet count: a retrospective cross-sectional study

INTRODUCTION Thrombocytopenia is a potential complication of hemodialysis (HD), and its occurrence has been described even with highly biocompatible polysulfone (PSf) membranes. Dialysis units routinely monitor platelet (PLT) count at the beginning of HD sessions. However, considering that the long-term effects on PLT count could easily be missed, the prevalence of HD-related thrombocytopenia c...

متن کامل

Relationship between platelet count and hemodialysis membranes

BACKGROUND One factor associated with poor outcomes in hemodialysis patients is exposure to a foreign membrane. Older membranes are very bioincompatible and increase complement activation, cause leukocytosis by activating circulating factors, which sequesters leukocytes in the lungs, and activates platelets. Recently, newer membranes have been developed that were designed to be more biocompatib...

متن کامل

Advances in Polysulfone-Based Membranes for Hemodialysis

The polysulfone-based membrane has been used in hemodialysis (HD) and it is continuously developed to maintain its sustainability on the subject of biocompatibility. During the polysulfone-based membrane development, several parameters should be considered to improve the membrane performances, such as excellent biocompatibility, appropriate ultrafiltration rate, and effective clearance of the t...

متن کامل

Effect of N-Acetylcysteine on Residual Renal Function in Chronic Haemodialysis Patients Treated with High-Flux Synthetic Dialysis Membranes: A Pilot Study

Background. Preservation of residual renal function in chronic dialysis patients has proven to be a major predictor of survival. The aim of the present study was to investigate an ability of the combined use of N-acetylcysteine and high-flux biocompatible haemodialysis membranes to improve residual renal function in haemodialysis patients. Patients and Methods. Chronic haemodialysis patients wi...

متن کامل

Resolution of Dialyzer Membrane-Associated Thrombocytopenia with Use of Cellulose Triacetate Membrane: A Case Report

Blood and dialyzer membrane interaction can cause significant thrombocytopenia through the activation of complement system. The extent of this interaction determines the biocompatibility of the membrane. Although the newer synthetic membranes have been shown to have better biocompatibility profile than the cellulose-based membranes, little is known about the difference in biocompatibility betwe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2012  شماره 

صفحات  -

تاریخ انتشار 2012