Multipole shimming of permanent magnets using harmonic corrector rings.

نویسندگان

  • R C Jachmann
  • D R Trease
  • L-S Bouchard
  • D Sakellariou
  • R W Martin
  • R D Schlueter
  • T F Budinger
  • A Pines
چکیده

Shimming systems are required to provide sufficient field homogeneity for high resolution nuclear magnetic resonance (NMR). In certain specialized applications, such as rotating-field NMR and mobile ex situ NMR, permanent magnet-based shimming systems can provide considerable advantages. We present a simple two-dimensional shimming method based on harmonic corrector rings which can provide arbitrary multipole order shimming corrections. Results demonstrate, for example, that quadrupolar order shimming improves the linewidth by up to an order of magnitude. An additional order of magnitude reduction is in principle achievable by utilizing this shimming method for z-gradient correction and higher order xy gradients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Magnetic field shimming of a permanent magnet using a combination of pieces of permanent magnets and a single-channel shim coil for skeletal age assessment of children.

We adopted a combination of pieces of permanent magnets and a single-channel (SC) shim coil to shim the magnetic field in a magnetic resonance imaging system dedicated for skeletal age assessment of children. The target magnet was a 0.3-T open and compact permanent magnet tailored to the hand imaging of young children. The homogeneity of the magnetic field was first improved by shimming using p...

متن کامل

Theory and development of biplanar active shim coils for a permanent NMR analyzer

The general expression for magnetic induction in the z axis direction is derived from magnetic scalar potential, and magnetic induction for biplanar shimming coils (BSCs) is also derived from magnetic vector potentials and Green functions, which simultaneously include Sin and Cos harmonic fields. The relationship between these expressions is discussed, and we show they are partially consistent....

متن کامل

Study of the Magnetic Coupling between Quadrupole and Dipole Corrector Magnets for the Kek B-factory

Most of the quadrupole magnets in the KEK B-factory are accompanied by a set of vertical and horizontal dipole corrector magnets in both the LER and HER rings[1]. The typical separation between a quadrupole and a dipole corrector magnet is 202 mm, as measured from the laminated ends. This corresponds to ~3.7 (2.4) times of the bore radius of a quadrupole magnet in the arc (straight) sections. S...

متن کامل

Study on Shimming Method for Open Perma- Nent Magnet of Mri

The shimming method used for producing high field homogeneity of the open permanent main magnet for magnetic resonance imaging (MRI) is researched in this paper. The central shimming method based on integer programming is proposed, which fulfills the combination of optimal theory and the practical manual shimming. The formulation of shimming is solved by using Lingo software and the numerical a...

متن کامل

How does an MR scanner operate?

The purpose of the magnet is to provide a uniform magnetic field at all points in the bore of the magnet to align mobile protons within the patient. The strength of the magnetic field is measured in units of testa or gauss-1.0 T equals 10 000 G. The magnetic field produced by the magnet is typically 30 000 times stronger than the magnetic field of the earth. Because it is not possible to obtain...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 78 3  شماره 

صفحات  -

تاریخ انتشار 2007