Reliability of the hip-to-ankle radiograph in determining the knee and implant alignment after total knee arthroplasty.
نویسندگان
چکیده
Hip-to-ankle radiographs have been used to evaluate lower limb alignment before and after total knee arthroplasty. However, earlier studies have inappropriately used correlation to assess the reproducibility of the radiographs. We determined the reliability of the hip-to-ankle radiograph using the Bland-Altman analysis. Two consecutive hip-to-ankle radiographs were obtained in 52 patients (52 knees) after total knee arthroplasty. There was an excellent agreement between mechanical axis angles, tibiofemoral angles, and femoral and tibial component alignment in the two radiographs. There was also an excellent agreement between all intra and interobserver analyses. The hip-to-ankle radiograph appears to be a reliable and reproducible means for determining the alignment of the knee in the coronal plane after total knee arthroplasty. In routine follow-up, the short anteroposterior knee radiograph may provide sufficient information. However, only the hip-to-ankle radiograph provides accurate information on the weightbearing mechanical axis in patients with suspected lower limb malalignment.
منابع مشابه
The Effect of Total Knee Arthroplasty on Hindfoot Alignment in Patients with Severe Genu Varum and Genu Valgum
Background: The maintenance of deformity in the ankle and hindfoot after correction of knee deformity following kneearthroplasty may cause abnormal tension in the knee and patient dissatisfaction. The aim of this study was to determinethe effect of knee arthroplasty on the hindfoot alignment in patients with severe genu varum and valgum.Methods: A total of 84 patients with pri...
متن کاملComparison of Clinical, Functional, and Radiological Outcomes of Total Knee Arthroplasty Using Conventional and Patient-Specific Instrumentation
Background: Recently, patient-specific instrumentation (PSI) systems have been developed in order to increase theaccuracy of component positioning during total knee arthroplasty (TKA); however, the findings of previous studies arecontroversial in this regard. In the current randomized clinical study, the outcomes of computer tomography (CT)-basedPS (patient specific)-guided TK...
متن کاملRestoration of the Mechanical Axis in Total Knee Artrhoplasty Using Patient-Matched Technology Cutting Blocks. A Retrospective Study of 132 Cases
Background: The aim of this study is to evaluate the accuracy of bone cuts and the resultant alignment, using theMyKnee patient specific cutting blocks.Methods: We retrospectively reviewed 132 patients undergoing primary TKR for osteoarthritis by one single surgeon.The operative time, the preoperative Hip-Knee-Ankle (HKA) axis based on the CT-scan, the postoperative HKA axisbased on long axis s...
متن کاملComparison of Double and Single Leg Weight-Bearing Radiography in Determining Knee Alignment
Background: Knee malalignment is an important modifiable cause of osteoarthritis (OA). Surgical therapeutic procedures depend on proper knee alignment assessment. The purpose of this study was to compare knee alignment parameters between double and single leg weight-bearing radiographs and to evaluate the reproducibility of inter- and intra-observer measurements. Methods: One hundred eight p...
متن کاملORRECTION OF HINDFOOT ALIGNMENT AFTER TOTAL KNEE ARTHROPLASTY IN PATIENTS WITH SEVERE KNEE VARUS OR VALGUS DEFORMITY
This was Presented in 5th International Congress of Iranian Iranian Society of Knee Surgery, Arthroscopy, and Sports Traumatology (ISKAST), 14-17 Feb 2018- Kish, Iran
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta orthopaedica Belgica
دوره 77 3 شماره
صفحات -
تاریخ انتشار 2011