Interobserver and Intraobserver Reliability of Clinical Assessments in Knee Osteoarthritis.

نویسندگان

  • Nasimah Maricar
  • Michael J Callaghan
  • Matthew J Parkes
  • David T Felson
  • Terence W O'Neill
چکیده

OBJECTIVE Clinical examination of the knee is subject to measurement error. The aim of this analysis was to determine interobserver and intraobserver reliability of commonly used clinical tests in patients with knee osteoarthritis (OA). METHODS We studied subjects with symptomatic knee OA who were participants in an open-label clinical trial of intraarticular steroid therapy. Following standardization of the clinical test procedures, 2 clinicians assessed 25 subjects independently at the same visit, and the same clinician assessed 88 subjects over an interval period of 2-10 weeks; in both cases prior to the steroid intervention. Clinical examination included assessment of bony enlargement, crepitus, quadriceps wasting, knee effusion, joint-line and anserine tenderness, and knee range of movement (ROM). Intraclass correlation coefficients (ICC), estimated kappa (κ), weighted kappa (κω), and Bland-Altman plots were used to determine interobserver and intraobserver levels of agreement. RESULTS Using Landis and Koch criteria, interobserver κ scores were moderate for patellofemoral joint (κ = 0.53) and anserine tenderness (κ = 0.48); good for bony enlargement (κ = 0.66), quadriceps wasting (κ = 0.78), crepitus (κ = 0.78), medial tibiofemoral joint tenderness (κ = 0.76), and effusion assessed by ballottement (κ = 0.73) and bulge sign (κω = 0.78); and excellent for lateral tibiofemoral joint tenderness (κ = 1.00), flexion (ICC = 0.97), and extension (ICC = 0.87) ROM. Intraobserver κ scores were moderate for lateral tibiofemoral joint tenderness (κ = 0.60); good for crepitus (κ = 0.78), effusion assessed by ballottement test (κ = 0.77), patellofemoral joint (κ = 0.66), medial tibiofemoral joint (κ = 0.64), and anserine tenderness (κ = 0.73); and excellent for effusion assessed by bulge sign (κω = 0.83), bony enlargement (κ = 0.98), quadriceps wasting (κ = 0.83), flexion (ICC = 0.99), and extension (ICC = 0.96) ROM. CONCLUSION Among individuals with symptomatic knee OA, the reliability of clinical examination of the knee was at least good for the majority of clinical signs of knee OA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The interobserver and intraobserver reliability of the Fernandez classification of distal radius fracture

 Abstract Background: With increasing knowledge concerning fractures of the distal radius, different classifications have been proposed. Reliability of most of these classifications has been assessed. The Fernandez classification has never been assessed for intraobserver and interobserver reliability, although this classification is commonly used. Methods: Five observers including one attending...

متن کامل

Observer reliability in the arthroscopic classification of osteoarthritis of the knee.

We studied 19 videotaped knee arthroscopies in 19 patients with mild to moderate osteoarthritis (OA) of the knee in order to compare the intraobserver and interobserver reliability and the patterns of disagreement between four orthopaedic surgeons. The classifications of OA of Collins, Outerbridge and the French Society of Arthroscopy were used. Intraobserver and interobserver agreements using ...

متن کامل

Reproducibility assessment of different descriptions of the Kellgren and Lawrence classification for osteoarthritis of the knee☆

OBJECTIVE To assess the inter- and intraobserver reproducibility of the original version and different descriptions of the Kellgren and Lawrence classification used in epidemiological studies for osteoarthritis of the knee. METHODS The study included 72 patients with osteoarthritis of the knee. Three medical members of the Brazilian Society of Knee Surgery were invited to evaluate the images....

متن کامل

Evaluation of a method for clinically assessing osteoarthritis of the knee.

A system for assessing symptoms (pain, stiffness, gelling) and signs (local temperature, effusion, tenderness, synovial swelling, popliteal cyst, crepitus) of osteoarthritis of the knee has been developed. The system has been assessed for intra- and interobserver variation using normal and osteoarthritic knees. Intraobserver variability is low for all indices but interobserver variability is hi...

متن کامل

Validation of a novel smartphone accelerometer-based knee goniometer.

Loss of full knee extension following anterior cruciate ligament surgery has been shown to impair knee function. However, there can be significant difficulties in accurately and reproducibly measuring a fixed flexion of the knee. We studied the interobserver and the intraobserver reliabilities of a novel, smartphone accelerometer-based, knee goniometer and compared it with a long-armed conventi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of rheumatology

دوره 43 12  شماره 

صفحات  -

تاریخ انتشار 2016