A novel approach: how an intracoronary shunt proved to be lifesaving.

نویسندگان

  • Karen Booth
  • Gareth J Hooks
  • Peter C E Mhandu
  • Haralabos Parissis
چکیده

Outcomes and complications following internal massage in cardiac surgery are unknown due to the lack of cumulative effort to capture those events and subsequently developing a registry. Therefore, under the circumstances there are no algorithms defined in the literature. This case report outlines the importance of sound decision-making under pressure in order to achieve a favourable outcome. A potential solution is outlined to a very complex and rare problem: anastomotic disruption during internal cardiac massage in an intensive care unit setting, demonstrating the use of an intracoronary shunt for initial stabilization prior to a definitive procedure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه‌ی نتایج استفاده از شانت داخل عروق کرونر در عمل بای‌پس عروق کرونر بدون پمپ نسبت به عدم استفاده از آن

Background and Objective: Off pump coronary artery bypass graft can be done with or without using intracoronary shunt. We have compared these two methods in early postoperative period, in this study. Materials and Methods: 208 candidate patients for off pump coronary artery bypass graft were devided in to two groups randomly for using intracoronary shunt or not. Variables including peri and pos...

متن کامل

A Novel Reference Current Calculation Method for Shunt Active Power Filters using a Recursive Algebraic Approach

This paper presents a novel method to calculate the reference source current and the referencecompensating current for shunt active power filters (SAPFs). This method first calculates theamplitude and phase of the fundamental load current from a recursive algebraic approach blockbefore calculating the displacement power factor. Next, the amplitude of the reference mains currentis computed with ...

متن کامل

Overview of Intracoronary Brachytherapy for in-Stent Restenosis of a Drug-Eluting Stent

Percutaneous coronary intervention with stenting is considered recently as the most common procedure for the treatment of symptomatic coronary. The article reviewed 41 studies published during 1997-2019 on intracoronary brachytherapy for in-stent restenosis of a drug-eluting stent. Intracoronary radiation therapy was finally confirmed in the setting of in-stent restenosis using as adjunctive th...

متن کامل

Intracoronary shunt reduces postoperative troponin leaks: a prospective randomized study.

OBJECTIVE The purpose of this study was to evaluate whether intracoronary shunt usage reduced the myocardial damage on the basis of the cardiac markers when compared with the shuntless anastomosis in off-pump coronary artery bypass grafting (OPCABG) surgery of isolated left anterior descending artery lesions. METHODS Forty patients who had stable angina with isolated left anterior descending ...

متن کامل

Flow simulation of the intracoronary shunt tube for off-pump coronary artery bypass.

INTRODUCTION To simulate blood flow provided by the intracoronary shunt tube, and to clarify whether this method is actually suitable for Off-pump coronary artery bypass (OPCAB), we investigated the efficacy of the intracoronary shunt tube in a theoretical model on the basis of fluid dynamics. METHODS Fluid dynamics analysis was performed to simulate flow decrease after attachment on an intra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of surgical case reports

دوره 2015 12  شماره 

صفحات  -

تاریخ انتشار 2015