Double-umbrella closure of atrial defects. Initial clinical applications.

نویسندگان

  • J J Rome
  • J F Keane
  • S B Perry
  • P J Spevak
  • J E Lock
چکیده

Forty patients were catheterized for closure of atrial septal defects with the Rashkind patent ductus arteriosus umbrella device, a modified Rashkind umbrella device, and the newly designed Lock Clamshell Occluder. Patients weighed 8 kg or more (a requirement for transvenous access with the 11F delivery sheath) and had defects suitable for closure based on two-dimensional echocardiography. The new device was at least 1.6 times the diameter of the atrial septal defect as determined by balloon sizing at catheterization. Patients were followed up by telephone, clinical examination, and echocardiography at 6 months. We attempted closure in 34 patients, with atrial septal defects ranging in diameter from 3 to 22 mm; device sizes ranged from 17 to 33 mm. Initial device position immediately after release was correct in all patients. A cerebral embolus occurred in one elderly patient before device placement--the patient died 1 week later. Two instances of early device embolization occurred, and devices were retrieved by catheter without complication. Follow-up of 31 patients discharged with devices in place, for a total of 31 patient-years, has yielded no umbrella-related complications. Adequate imaging studies in 19 patients 6.5 months after device placement revealed no atrial shunt in 12; residual flow through separate, previously unrecognized atrial septal defects occurred in two; and small residual leaks (less than 3 mm) around devices were present in five patients. This initial success indicates that double-umbrella closure of atrial septal defects will aid in the treatment of intracardiac defects.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcatheter closure of atrial septal defects. Experimental studies.

Recent experience with the spring-loaded patent ductus arteriosus (PDA) occluder has demonstrated several advantages of this device in the closure of intracardiac defects compared with previously described techniques. Pathologic and animal model studies were performed to identify which atrial septal defects (ASDs) might be suitable for device closure and to test a new septal closure double umbr...

متن کامل

Extending the limits of transcatheter closure of atrial septal defects with the double umbrella device (CardioSEAL).

OBJECTIVE To report initial findings from a selected group of patients with morphological variations of the atrial septal defect who underwent transcatheter closure with a second generation redesigned double umbrella device. PATIENTS Two patients with abnormal location of the oval fossa and partial deficiency of the septal rim, three patients with multiple defects, and two patients with a mul...

متن کامل

Transcatheter closure of atrial septal defects. Past, present, and future.

T ranscatheter closure of atrial septal defects has been a dream of pediatric cardiologists for the past 25 years. The study by Rome and coworkers in this issue of Circulation,' the latest advance in a 20-year sequence, suggests that the dream is now almost a reality. To understand the true significance of the present study, a brief review of past work in this area is important. In 1976, King a...

متن کامل

Evaluation of Clinical Course in Children and Adolescents with Atrial Septal Defects

Background Atrial septal defects (ASDs) are the most common third congenital heart defects. This study aimed to evaluate the clinical course of ASDs and the relationship between its complications, location closure and size. Materials and Methods: This cross-sectional study was conducted...

متن کامل

Intraoperative apical ventricular septal defect closure using a modified Rashkind double umbrella.

OBJECTIVE To demonstrate the safety and efficacy of intraoperative apical ventricular septal defect (VSD) closure using a modified Rashkind double umbrella. DESIGN Descriptive study of all patients in whom intraoperative device closure of apical VSDs was attempted. SETTING A tertiary referral centre. PATIENTS Four patients with an apical VSD requiring closure, during the period January 19...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 82 3  شماره 

صفحات  -

تاریخ انتشار 1990