PET with FDG-labeled leukocytes versus scintigraphy with 111In-oxine-labeled leukocytes for detection of infection.
نویسندگان
چکیده
PURPOSE To compare prospectively the accuracy of positron emission tomography (PET) with leukocytes labeled in vitro with (18)F fluorodeoxyglucose (FDG) versus that of conventional scintigraphy with leukocytes labeled in vitro with (111)In oxine in patients suspected of having infection. MATERIALS AND METHODS This HIPAA-compliant study had institutional review board approval; informed consent was obtained from all patients. Patients were 25 men and 26 women aged 32-86 years. In vitro labeling of autologous human leukocytes with FDG and (111)In-oxine was performed according to published methods. Labeling efficiencies and cell viability were determined. Imaging was performed 2.5-5.8 hours after injection of 196-315 MBq of FDG-labeled leukocytes and approximately 24 hours after injection of 17-25 MBq of (111)In-oxine-labeled leukocytes. Forty-three (20 men, 23 women; mean age, 59 years; range, 32-86 years) patients could be successfully imaged with both tracers. Six patients were not injected with FDG-labeled leukocytes because of low labeling efficiency (<35%). Two patients were injected with FDG-labeled leukocytes but were not imaged. One reader interpreted all results as positive or negative for infection. Imaging results were compared with final diagnoses. Labeling efficiencies and cell viabilities were compared by using the paired t test. Differences between PET and scintigraphy were determined by using the McNemar test. RESULTS For the 43 patients who were imaged with both tracers, labeling efficiency of FDG was lower than that of (111)In oxine (72% +/- 8 [standard deviation] vs 90% +/- 5, P < .001). Viability of FDG-labeled leukocytes was not different from that of (111)In-oxine-labeled leukocytes (98% +/- 1 vs 97% +/- 3). There were no differences between FDG PET and (111)In scintigraphy in terms of sensitivity (87% vs 73%), specificity (82% vs 86%), or accuracy (84% vs 81%). CONCLUSION PET with FDG-labeled leukocytes was comparable to scintigraphy with (111)In-oxine-labeled leukocytes. Further investigation in a larger population with dedicated PET or PET/computed tomography seems warranted.
منابع مشابه
No difference in sensitivity for occult infection between tropolone- and oxine-labeled indium-111 leukocytes.
There is considerable disagreement as to whether oxine or tropolone is the best labeling agent for indium leukocytes. We have previously looked at the sensitivity of oxine-labeled 111In leukocyte scans for occult infections and now present a similar group of patients imaged with tropolone-labeled 111In leukocytes. Thirty-four patients (38 studies) with possible occult infection were prospective...
متن کاملDetection of subacute infectious foci with indium-111-labeled autologous leukocytes and indium-111-labeled human nonspecific immunoglobulin G: a prospective comparative study.
In 35 patients suspected of an infectious focus, the outcome of scintigraphy with 111In-labeled autologous leukocytes (WBC) and 111In-labeled human nonspecific immunoglobulin G (IgG) was evaluated in a prospective comparative study. Clinical, roentgenologic and microbiologic findings were considered to be proof of the presence of infection or inflammation. In this group of patients with mainly ...
متن کاملUsefulness of indium-111-oxine-labeled leukocyte scintigraphy in diagnosis of inflammation associated with chronic aortic dissection.
BACKGROUND Patients with chronic aortic dissection require monitoring for indications of disease progression. In present study, inflammation adjacent to associated aortic wall was evaluated by indium-111-oxine-labeled leukocyte scintigraphy, scince inflammation of the blood vessel wall often associates with progression of chronic aortic dissection. METHODS AND RESULTS Fifteen patients with ao...
متن کاملAbsent splenic uptake of indium-111-oxine-labeled autologous leukocytes in functional asplenia.
An incidental finding of absent splenic uptake of autologous, indium-111-oxine-labeled leukocytes in an immunosuppressed renal transplant recipient was documented to be associated with functional asplenia based on absence of technetium-99m-sulfur colloid clearance by a morphologically normal spleen. The patient had recently suffered an episode of disseminated varicella infection that might have...
متن کاملPost Mortem Leukocyte Scintigraphy in Juvenile Pigs with Experimentally Induced Osteomyelitis
We have previously demonstrated that 111In-labeled autologous leukocyte scintigraphy is able to detect osteomyelitis in living juvenile pigs. In animal research studies, it may well be an advantage if the animals could be scanned after euthanasia. Applying traditional scanning of living animals to euthanized animals will render anaesthesia unnecessary and be ideal for obtaining good and reliabl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiology
دوره 238 3 شماره
صفحات -
تاریخ انتشار 2006