Intravascular ultrasound and histology findings in very late bare-metal stent thrombosis.
نویسندگان
چکیده
Very late thrombosis in an implanted bare-metal stent is a very uncommon event outside the context of brachytherapy and few data about its pathophysiology are available. We performed an intravascular ultrasound study during primary angioplasty in five patients with very late bare-metal stent thrombosis and carried out a histological analysis of the material removed by manual thrombectomy. The mean time from the index procedure was 7 ± 4 years. Intravascular ultrasound findings were: calcified atherosclerosis with in-stent plaque rupture, complex plaque in the distal segment of the stent, in-stent neointimal proliferation associated with underexpansion, and severe in-stent proliferation. Histological findings were consistent with the intravascular ultrasound images: recent thrombus with areas of old thrombosis in all cases and remnant atheromatous plaque and endothelium. Consequently, in-stent or distal stent atherosclerosis progression and progressive neointimal proliferation were the likely pathophysiological mechanisms.
منابع مشابه
Correlation of intravascular ultrasound findings with histopathological analysis of thrombus aspirates in patients with very late drug-eluting stent thrombosis.
BACKGROUND Intravascular ultrasound of drug-eluting stent (DES) thrombosis (ST) reveals a high incidence of incomplete stent apposition (ISA) and vessel remodeling. Autopsy specimens of DES ST show delayed healing and hypersensitivity reactions. The present study sought to correlate histopathology of thrombus aspirates with intravascular ultrasound findings in patients with very late DES ST. ...
متن کاملVery late stent thrombosis with bare-metal stent: identifying severe stent malapposition and underexpansion by intravascular ultrasound
A 60-year-old man with a history of implantation of two bare-metal stents 2 years prior presented to the emergency department with new-onset chest pain. He has been regularly taking angiotensinconverting enzyme inhibitors, beta blockers and aspirin. Aspirin was suspended for 10 days prior to the current hospitalization in order to perform surgery to remove a kidney tumor. He underwent coronary ...
متن کاملHeterogeneous Intravascular Ultrasound Findings of Stent Thrombosis
Objective The underlying mechanisms of stent thrombosis are not completely understood. Methods We experienced 12 definite stent thrombosis cases (1 early, 1 late, and 10 very late) at our hospital from July 2011 to April 2016 and evaluated the possible causes of stent thrombosis by intravascular ultrasound (IVUS). Results Five different potential morphological causes of stent thrombosis (neoath...
متن کاملLatest on the pathology of drug-eluting stents
The introduction of drug-eluting stents (DES) has significantly reduced restenosis when compared with bare-metal stents and are considered the standard of care in the treatment of symptomatic coronary artery disease. However, late stent thrombosis (LST), potentially resulting in a fatal occlusion of the vessel, emerged as a major concern in first-generation DES (polymer-based sirolimusand pacli...
متن کاملIntravascular ultrasound findings in patients with very late stent thrombosis after either drug-eluting or bare-metal stent implantation.
OBJECTIVES This study compared intravascular ultrasound (IVUS) findings at drug-eluting stent (DES) and bare-metal stent (BMS) sites in patients with very late stent thrombosis (VLST). BACKGROUND VLST is being increasingly identified since the introduction of DES. VLST can also develop after BMS placement, but the underlying mechanisms remain unknown. METHODS A total of 30 consecutive VLST ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Revista espanola de cardiologia
دوره 63 12 شماره
صفحات -
تاریخ انتشار 2010