A randomized comparison of drug-eluting balloon versus everolimus-eluting stent in patients with bare-metal stent-in-stent restenosis: the RIBS V Clinical Trial (Restenosis Intra-stent of Bare Metal Stents: paclitaxel-eluting balloon vs. everolimus-eluting stent).

نویسندگان

  • Fernando Alfonso
  • Maria Jose Pérez-Vizcayno
  • Alberto Cárdenas
  • Bruno García Del Blanco
  • Bernhard Seidelberger
  • Andrés Iñiguez
  • Manuel Gómez-Recio
  • Mónica Masotti
  • M Teresa Velázquez
  • Juan Sanchís
  • Arturo García-Touchard
  • Javier Zueco
  • Armando Bethencourt
  • Rafael Melgares
  • Angel Cequier
  • Antonio Dominguez
  • Vicente Mainar
  • José R López-Mínguez
  • José Moreu
  • Vicens Martí
  • Raúl Moreno
  • Pilar Jiménez-Quevedo
  • Nieves Gonzalo
  • Cristina Fernández
  • Carlos Macaya
چکیده

OBJECTIVES This study sought to compare the efficacy of drug-eluting balloons (DEB) with that of everolimus-eluting stents (EES) in patients with bare-metal stents (BMS) in-stent restenosis (ISR). BACKGROUND Treatment of patients with ISR remains a challenge. METHODS This was a prospective, multicenter, randomized trial comparing DEB with EES in patients with bare-metal stents (BMS) in-stent restenosis (ISR). The primary endpoint was the minimal lumen diameter at 9 months' follow-up. RESULTS A total of 189 patients with BMS-ISR from 25 Spanish sites were included (95 were allocated to DEB and 94 to EES). Procedural success was achieved in all patients. At late angiography (median 249 days; 92% of eligible patients), patients in the EES arm had a significantly larger minimal lumen diameter (2.36 ± 0.6 mm vs. 2.01 ± 0.6 mm, p < 0.001; absolute mean difference: 0.35 mm; 95% confidence interval [CI]: 0.16 to 0.53) and a lower percent of diameter stenosis (13 ± 17% vs. 25 ± 20%, p < 0.001). However, late loss (0.04 ± 0.5 mm vs. 0.14 ± 0.5 mm, p = 0.14) and binary restenosis rate (4.7% vs. 9.5%, p = 0.22) were very low and similar in both groups. Clinical follow-up (median 365 days) was obtained in all (100%) patients. Occurrences of the combined clinical outcome measure (cardiac death, myocardial infarction, and target vessel revascularization; 6% vs. 8%; hazard ratio [HR]: 0.76; 95% CI: 0.26 to 2.18, p = 0.6) and the need for target vessel revascularization (2% vs. 6%; HR: 0.32: 95% CI: 0.07 to 1.59, p = 0.17) were similar in the 2 groups. CONCLUSIONS In patients with BMS-ISR, both DEB and EES provided excellent clinical results with a very low rate of clinical and angiographic recurrences. However, compared with DEB, EES provide superior late angiographic findings. (Restenosis Intra-stent of Bare Metal Stents: Paclitaxel-eluting Balloon vs. Everolimus-eluting Stent [RIBS V]; NCT01239953).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Everolimus-Eluting Stents in Patients With Bare-Metal and Drug-Eluting In-Stent Restenosis: Results From a Patient-Level Pooled Analysis of the RIBS IV and V Trials.

BACKGROUND Treatment of patients with drug-eluting stent (DES) in-stent restenosis (ISR) is more challenging than that of patients with bare-metal stent ISR. However, the results of everolimus-eluting stents (EES) in these distinct scenarios remain unsettled. METHODS AND RESULTS A pooled analysis of the RIBS IV (Restenosis Intra-Stent of Drug-Eluting Stents: Paclitaxel-Eluting Balloon vs Ever...

متن کامل

Everolimus-eluting coronary stents

Bare metal stents enabled a reduction in the risk of early procedural complications and restenosis in comparison with balloon angioplasty alone, but introduced a new and device-specific iatrogenic condition, ie, in-stent restenosis due to increased neointimal hyperplasia. Sirolimus- and paclitaxel-eluting stents reduce restenosis and the need for new revascularizations in comparison with bare m...

متن کامل

Comparison of the Efficacy of Paclitaxel-Eluting Balloon Catheters and Everolimus-Eluting Stents in the Treatment of Coronary In-Stent Restenosis

Coronary stent implantation has significantly improved percutaneous coronary intervention and enabled the management of early complications of plain balloon angioplasty (POBA). By preventing elastic recoil and constrictive remodeling, coronary stent implantation decreases the frequency of restenosis after percutaneous coronary intervention. However, a new complication has accompanied these impr...

متن کامل

Update on the everolimus-eluting coronary stent system: results and implications from the SPIRIT clinical trial program

Drug-eluting stents (DES) have had a major impact in interventional cardiology. Compared to bare metal stents, they significantly reduce restenosis and the need for target vessel revascularization. Four DES are available in the US, the first-generation sirolimus-eluting (Cypher((R))) and paclitaxel-eluting (Taxus((R))) stents and later approved second-generation everolimus-eluting (Xience V((R)...

متن کامل

Efficacy of a seal-wing paclitaxel-eluting balloon catheters in the treatment of bare metal stent restenosis

BACKGROUND Our study aimed to compare the efficacy of seal-wing paclitaxel-eluting balloon catheters (PEB) with iopromide-coated PEB and everolimus-eluting stents (EES) for treating bare metal stent restenosis (BMS-ISR). METHODS We enrolled 64 patients with 69 BMS-ISR. The control group comprised patients from the iopromide-PEB and EES arms of a previous TIS study. The primary end-point was 1...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 63 14  شماره 

صفحات  -

تاریخ انتشار 2014