Localized harmonic motion imaging: theory, simulations and experiments.
نویسندگان
چکیده
Several techniques have been developed in an effort to estimate mechanical properties of tissues. These techniques typically estimate static or harmonic motion resulting from an externally or internally applied mechanical stimulus. In this paper, we discuss the advantages of utilizing a new technique that performs radiofrequency (RF) signal tracking to estimate the localized oscillatory motion resulting from the harmonic radiation force produced by two focused ultrasound (US) transducer elements with overlapping beams oscillating at distinct frequencies. Finite-element and Monte-Carlo simulations were performed to characterize the range of oscillatory displacements produced by a harmonic radiation force. In the experimental verification, three transducers were used: two single-element focused transducers and one lead zirconate-titanate (PZT) composite 16-element probe. Four agar gels were utilized to determine the effect of stiffness on the motion amplitude. Estimates of the displacement relative to the initial position (i.e., at the onset of the application of the radiation force) were obtained during the application of the radiation force that oscillated at frequencies ranging between 200 Hz and 800 Hz. In the simulations, the estimated oscillatory displacement spanned from -800 to 600 microm and the frequencies of excitation could easily be estimated from the temporal variation of the displacement. In addition, a frequency upshift (on the order of tens of Hz) was estimated with stiffness increase. Furthermore, an exponential decrease of the displacement amplitude with stiffness was observed at all frequencies investigated. An M-mode version to depict both the spatial and temporal variations of the locally induced displacement was used. In experiments with gels of different stiffness, the resulting amplitude of the harmonic displacement estimated oscillated at the same frequencies and ranged from -300 to 250 microm. An exponential decrease of the displacement amplitude with the gel stiffness was also observed. In tissue experiments, the results showed that the method is feasible in tissues and that focused US surgery (FUS) ablation can be detected. These preliminary results demonstrate the feasibility of imaging localized harmonic motion as induced by an oscillatory US radiation force. Due to the highly localized and harmonic nature of the estimated response, this technique may be proven to be highly suitable for simple and accurate estimation of the elastic modulus variation in tissues due to disease.
منابع مشابه
Dynamic Stability Analysis of a Beam Excited by a Sequence of Moving Mass Particles
In this paper, the dynamic stability analysis of a simply supported beam carrying a sequence of moving masses is investigated. Many applications such as motion of vehicles or trains on bridges, cranes transporting loads along their span, fluid transfer pipe systems and the barrel of different weapons can be represented as a flexible beam carrying moving masses. The periodical traverse of masses...
متن کاملSimulation study of amplitude-modulated (AM) harmonic motion imaging (HMI) for stiffness contrast quantification with experimental validation.
The objective of this study is to show that Harmonic Motion Imaging (HMI) can be used as a reliable tumor-mapping technique based on the tumor's distinct stiffness at the early onset of disease. HMI is a radiation-force-based imaging method that generates a localized vibration deep inside the tissue to estimate the relative tissue stiffness based on the resulting displacement amplitude. In this...
متن کاملOn Interaction of T S Waves and 3 D Localized Disturbance in a Divergent Flow Under Zero Pressure Gradient
To simulate the effect of free st ream turbulence on turbulent spot formation, experiments were conducted on the interaction of localized three-dimensional disturbances with the harmonic waves in a laminar boundary layer on a flat plate. Experiments conducted in three-dimensional diverging flow (but zero pressure gradient) show, while individually the disturbances decay downstream, their intera...
متن کاملSingle-element focused ultrasound transducer method for harmonic motion imaging.
The harmonic motion imaging (HMI) technique for simultaneous monitoring and generation of ultrasound therapy using two separate focused ultrasound transducer elements was previously demonstrated. In this study, a new HMI technique is described that images tissue displacement induced by a harmonic radiation force using a single focused-ultrasound element. A wave propagation simulation model firs...
متن کاملLocalized and propagating surface plasmon resonances in aperture-based third harmonic generation.
We investigate the influence of localized and propagating surface plasmons on third harmonic generation from rectangular apertures in metal films. We designed optimal aperture array structures by using finite-difference time-domain simulations with nonlinear scattering theory. From this design space, we fabricated and measured the third harmonic in the region of maximal performance. We find the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ultrasound in medicine & biology
دوره 29 10 شماره
صفحات -
تاریخ انتشار 2003