Rebound tonometry in conscious, conditioned mice avoids the acute and profound effects of anesthesia on intraocular pressure.

نویسندگان

  • Thomas V Johnson
  • Shan Fan
  • Carol B Toris
چکیده

AIMS The aims of this study were to evaluate the accuracy, repeatability, and safety of multiple intraocular pressure (IOP) measurements by a commercially available rebound tonometer in conscious, conditioned mice, and to characterize the acute and profound effects of anesthesia on IOP in mice. METHODS To test the accuracy of the tonometer, IOPs of CD-1 mice under ketamine/xylazine anesthesia were experimentally set and monitored with a water manometer/transducer system following transcorneal cannulation while simultaneously performing tonometry. The long- and short-term repeatability of the tonometer was tested in conscious, restrained mice, as measurements were taken once-daily in the afternoon for 4 consecutive days. On day 5, IOPs were measured in the same mice once every 4 min for 32 min. On 2 separate days, mice were administered ketamine/xylazine or 2,2,2-tribromoethanol anesthesia, in a crossover design, and IOPs were measured once every 2 min for 32 min. Rebound tonometry was performed in conscious mice before and 1 hour after 1 drop of timolol maleate (10 microL of 0.5%) application to 1 eye. RESULTS IOP measurements by rebound tonometry correlated well with manometry for pressures between 8 and 38 mmHg (y = 0.98x - 0.32, R(2) = 0.94; P < 0.001). The average tonometric IOP was invariant over 4 days (range, 11.7-13.2 mmHg). IOPs dropped significantly ( P < or = 0.05) within 6 min (ketamine/xylazine) or 10 min (2,2,2-tribromoethanol) postadministration of anesthesia but not with conscious restraint. Timolol significantly (P < 0.001) lowered IOP from 12.8 +/- 0.3 (mean +/- standard error of the mean) to 10.1 +/- 0.6 mmHg, as measured by the tonometer. CONCLUSIONS Rebound tonometry can be used to obtain accurate IOP measurements in conscious, restrained mice while avoiding the rapid and profound ocular hypotensive effects of general anesthesia. Small changes in IOP with an aqueous-flow suppressant are readily detectable with conscious restraint that may be missed with chemical restraint.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Noninvasive measurement of rodent intraocular pressure with a rebound tonometer.

PURPOSE The present study evaluated the applicability of a rebound tonometer in measuring intraocular pressure (IOP) in rats and mice. METHODS The accuracy of the TonoLab rebound tonometer was determined in cannulated mouse and rat eyes. IOP was manipulated by changing reservoir height, and tonometer pressure readings were recorded by an independent observer. IOP values were recorded in consc...

متن کامل

Comparison of intraocular pressure measurement between rebound, non-contact and Goldmann applanation tonometry in treated glaucoma patients.

BACKGROUND To compare the intraocular pressure readings obtained with the iCare rebound tonometer and the 7CR non-contact tonometer with those measured by Goldmann applanation tonometry in treated glaucoma patients. DESIGN A prospective, cross-sectional study was conducted in a private tertiary glaucoma clinic. PARTICIPANTS OR SAMPLES One hundred nine (54 males : 55 females) patients includ...

متن کامل

Agreement of patient-measured intraocular pressure using rebound tonometry with Goldmann applanation tonometry (GAT) in glaucoma patients

This study aims to determine the agreement of patient-measured intraocular pressure (IOP) using rebound tonometry with ophthalmologist-measured IOP using Goldmann applanation tonometry (GAT). Fifty-three glaucoma patients used rebound tonometry (Icare ONE, Icare Finland Oy., Finland) to measure their own IOP in ambient environments for 1 week, 5 times per day. Clinic IOP measurements were perfo...

متن کامل

The measurement of intraocular pressure over positive soft contact lenses by rebound tonometry

PURPOSE To investigate if the accuracy of intraocular pressure (IOP) measurements using rebound tonometry over disposable hydrogel (etafilcon A) contact lenses (CL) is affected by the positive power of the CLs. METHODS The experimental group comprised 26 subjects, (8 male, 18 female). IOP measurements were undertaken on the subjects' right eyes in random order using a Rebound Tonometer (ICare...

متن کامل

Prostaglandin FP receptors do not contribute to 24-hour intraocular pressure variation in mice.

PURPOSE It is not known whether the prostaglandin FP receptor plays an important role in endogenous 24-hour regulation of intraocular pressure. The purpose of this study was to compare 24-hour intraocular pressure (IOP) in FP receptor-knockout mice with that of wild-type mice that have normal FP receptor expression. METHODS The 24-hour IOP profile was determined by rebound tonometry in FP-kno...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of ocular pharmacology and therapeutics : the official journal of the Association for Ocular Pharmacology and Therapeutics

دوره 24 2  شماره 

صفحات  -

تاریخ انتشار 2008