SU-E-T-385: Accelerated Beam Delivery with MLC Gaps in IMRT Fields.
نویسندگان
چکیده
PURPOSE By default, the 4-mm wide leaf-pairs of the Elekta Beam Modulator MLC not used for field shaping are moved to under the primary collimator to minimize the leakage dose. The trade-off is the increased beam delivery time in the case of IMRT. This study examines the dosimetric impact and improved delivery efficiency by allowing the unused leaf-pair as 2mm gap to stay within the PTV aperture during beam-on. METHODS The capability of the treatment planning system (Pinnacle) in modeling the central and off-axis dose through 2mm MLC gaps, respectively, was investigated. EBT film measurement performed in a solid water phantom was compared with the computed dose. For two representative IMRT cases, the dosimetric features of treatment plans generated with and without MLC gaps in the field were compared. Similarly, the delivery times for 13 IMRT cases with and without MLC gaps were compared. RESULTS The peak dose of the leaf gap computed with Pinnacle was dependent on dose grid resolution. The difference between a 0.5mm and 2mm dose grid was about 16.5% for 6MV and 15MV beam respectively. Using a 0.5mm dose grid, the maximum difference between measured and calculated dose was < 1% for a central axis gap, and < 3% for an off-axis gap. The maximum dose through a 2mm×4mm leaf gap was estimated < 10cGy for a typical IMRT plan. DVH comparison showed an increase of target dose up to 2% for the IMRT plans with gap, with minimal dose change to all critical structures. For the 13 IMRT cases, the beam delivery times were reduced by 27+/-9.7%, from 8.7+/-4.5 minutes to 6.5+/-4.0 minutes. CONCLUSIONS The beam delivery is accelerated by utilizing minimal gaps in the IMRT fields. The increased dose to the target is acceptable and is minimal to all critical structures.
منابع مشابه
Comparing dose in the build‐up region between compensator‐ and MLC‐based IMRT
The build-up dose in the megavoltage photon beams can be a limiting factor in intensity-modulated radiation therapy (IMRT) treatments. Excessive surface dose can cause patient discomfort and treatment interruptions, while underdosing may lead to tumor repopulation and local failure. Dose in the build-up region was investigated for IMRT delivery with solid brass compensator technique(compensator...
متن کاملMotion adaptive x-ray therapy: a feasibility study.
Intrafraction motion caused by breathing requires increased treatment margins for chest and abdominal radiotherapy and may lead to 'motion artefacts' in dose distributions during intensity modulated radiotherapy (IMRT). Technologies such as gated radiotherapy may significantly increase the treatment time, while breath-hold techniques may be poorly tolerated by pulmonarily compromised patients. ...
متن کاملA method for photon beam Monte Carlo multileaf collimator particle transport.
Monte Carlo (MC) algorithms are recognized as the most accurate methodology for patient dose assessment. For intensity-modulated radiation therapy (IMRT) delivered with dynamic multileaf collimators (DMLCs), accurate dose calculation, even with MC, is challenging. Accurate IMRT MC dose calculations require inclusion of the moving MLC in the MC simulation. Due to its complex geometry, full trans...
متن کاملSuperficial and peripheral dose in compensator‐based FFF beam IMRT
Flattening filter-free (FFF) beams produce higher dose rates. Combined with compensator-based intensity modulated radiotherapy (IMRT) techniques, the dose delivery for each beam can be much shorter compared to the flattened beam MLC-based or flattened beam compensator-based IMRT. This 'snap shot' IMRT delivery is beneficial to patients for tumor motion management. Due to softer energy, superfic...
متن کاملSU-E-T-378: IMRT Severity Scoring for TG-100: Do You Really Know?
PURPOSE Failure modes and effects analysis (FMEA) as defined in TG-100 has become a popular concept throughout the radiotherapy community. This risk mitigation technique involves detailed process mapping, analysis, and ranking of potential errors by means of a subjective, ordinal scoring system. This study aims to reduce the subjectivity of FMEA severity scoring for IMRT delivery by providing q...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 39 6Part16 شماره
صفحات -
تاریخ انتشار 2012