Defects in rotary nickel-titanium files after clinical use.

نویسندگان

  • B Sattapan
  • G J Nervo
  • J E Palamara
  • H H Messer
چکیده

The purpose of this study was to analyze the type and frequency of defects in nickel-titanium rotary endodontic files after routine clinical use, and to draw conclusions regarding the reasons for failure. All of the files (total: 378, Quantec Series 2000) discarded after normal use from a specialist endodontic practice over 6 months were analyzed. Almost 50% of the files showed some visible defect; 21% were fractured and 28% showed other defects without fracture. Fractured files could be divided into two groups according to the characteristics of the defects observed. Torsional fracture occurred in 55.7% of all fractured files, whereas flexural fatigue occurred in 44.3%. The results indicated that torsional failure, which may be caused by using too much apical force during instrumentation, occurred more frequently than flexural fatigue, which may result from use in curved canals.

منابع مشابه

Do NiTi instruments show defects before separation? Defects caused by torsional fatigue in hand and rotary nickel-titanium (NiTi) instruments which lead to failure during clinical use.

AIMS Visual and microscopic evaluation of defects caused by torsional fatigue in hand and rotary nickel titanium (NiTi) instruments. MATERIALS AND METHODS Ninety-six NiTi greater taper instruments which were routinely used for root canal treatment only in anterior teeth were selected for the study. The files taken include ProTaper for hand use, ProTaper Rotary files and Endowave rotary files....

متن کامل

The ability of different nickel-titanium rotary instruments to induce dentinal damage during canal preparation.

The purpose of this study was to compare the incidence of dentinal defects (fractures and craze lines) after canal preparation with different nickel-titanium rotary files. Two hundred sixty mandibular premolars were selected. Forty teeth were left unprepared (n = 40). The other teeth were prepared either with manual Flexofiles (n = 20) or with different rotary files systems: ProTaper (Dentsply-...

متن کامل

Decrease in the fatigue resistance of nickel-titanium rotary instruments after clinical use in curved root canals.

OBJECTIVE The changes in fatigue resistance of nickel-titanium rotary ProFile instruments after clinical use for shaping 10 curved molar root canals were evaluated in this study. STUDY DESIGN Twenty-five sets of files #20, #25, and #30 and tapers .04 and .06 were divided into 2 groups, one with 10 sets of new files that were tested in a fatigue test bench device as a control. The other, exper...

متن کامل

Use of nickel-titanium rotary files for root canal preparation in primary teeth.

This article reviews the use of nickel-titanium rotary files for root canal instrumentation in primary teeth. The pulpectomy technique is described and the advantages and disadvantages of using rotary files are discussed. Specific recommendations for the selection of materials and devices are made.

متن کامل

The Effects of Two Root Canal Irrigants and Different Instruments on Dentin Microhardness ( In Vitro Study)

Aims: To measure the microhardness of root canal dentin using two types of irrigating solutions( 0.2% Chlorhexidine and 5.25% Sodium Hypochlorite) with and with out use of different types of root canal files (Stainless Steel-K files, Nickel-Titanium K-files or rotary Nickel-Titanium files). Materials & methods: The teeth divided in to four groups according to the type of irrigating solutions th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

متن کامل
عنوان ژورنال:
  • Journal of endodontics

دوره 26 3  شماره 

صفحات  -

تاریخ انتشار 2000