Comparison of retinal and cerebral blood flow between continuous arterial spin labeling MRI and fluorescent microsphere techniques.

نویسندگان

  • Yen-Yu I Shih
  • Bryan H De La Garza
  • Shiliang Huang
  • Guang Li
  • Lin Wang
  • Timothy Q Duong
چکیده

PURPOSE To compare basal retinal and cerebral blood flow (BF) values using continuous arterial spin labeling (CASL) MRI and fluorescent microspheres. MATERIALS AND METHODS A total of 41 animals were used. BF was measured using an established microsphere technique (a mixture of 2.5 million 8 μm green and 0.5 million 10 μm blue fluorescent microspheres) and CASL MRI blood flow measurement in the rat retina and brain at 7 Tesla (T) and 11.7T, respectively. RESULTS Retinal BF by MRI was 1.18 ± 0.57 mL/g/min and choroidal BF was 8.14 ± 1.8 mL/g/min (n = 6). Microsphere retinal BF was 9.12 ± 2.8 μL/min per tissue and choroidal BF was 73.38 ± 44 μL/min per tissue (n = 18), corresponding to a retinal BF value of 1.22 ± 0.36 mL/g/min by means of a wet weight conversion. The wet-weight of the choroid could not be determined. To corroborate our findings, cerebral BF (CBF) by MRI was also analyzed. In the cerebral cortices, CBF was 0.91 ± 0.29 mL/g/min (n = 14) by CASL MRI and 1.09 ± 0.37 mL/g/min (n = 6) by microspheres. There were no significant differences found between MRI and microsphere blood flow in the retina and brain. CONCLUSION BF values in the rat retina and cerebral cortex by MRI are in agreement with those obtained by the microsphere technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cerebral blood flow quantification in the rat: a direct comparison of arterial spin labeling MRI with radioactive microsphere PET

BACKGROUND Arterial spin labeling magnetic resonance imaging (ASL-MRI) has been recognised as a valuable method for non-invasive assessment of cerebral blood flow but validation studies regarding quantification accuracy by comparison against an accepted gold standard are scarce, especially in small animals. We have conducted the present study with the aim of comparing ASL flow-sensitive alterna...

متن کامل

Mapping cerebrovascular reactivity using blood oxygen level-dependent MRI in Patients with arterial steno-occlusive disease: comparison with arterial spin labeling MRI.

BACKGROUND AND PURPOSE Blood oxygen level-dependent MRI (BOLD MRI) of hypercapnia-induced changes in cerebral blood flow is an emerging technique for mapping cerebrovascular reactivity (CVR). BOLD MRI signal reflects cerebral blood flow, but also depends on cerebral blood volume, cerebral metabolic rate, arterial oxygenation, and hematocrit. The purpose of this study was to determine whether, i...

متن کامل

Blood-flow MRI of Non-human Primate (Baboon) Retina

INTRODUCTION Advances in MRI technologies have made it possible to achieve multilayer resolution of the thin retina of only 276 micron thick (1). In rodent and cat retinas, three to seven MRI-resolved anatomical layers have been reported depending on whether contrast agent was used (1-3). Contrast-enhanced MRI following intravenously injection of Gd-DTPA revealed two unique (retinal and choroid...

متن کامل

Perfusion magnetic resonance imaging with continuous arterial spin labeling: methods and clinical applications in the central nervous system.

Several methods are now available for measuring cerebral perfusion and related hemodynamic parameters using magnetic resonance imaging (MRI). One class of techniques utilizes electromagnetically labeled arterial blood water as a noninvasive diffusible tracer for blood flow measurements. The electromagnetically labeled tracer has a decay rate of T1, which is sufficiently long to allow perfusion ...

متن کامل

Comparison of cerebral blood flow acquired by simultaneous [15O]water positron emission tomography and arterial spin labeling magnetic resonance imaging

Until recently, no direct comparison between [(15)O]water positron emission tomography (PET) and arterial spin labeling (ASL) for measuring cerebral blood flow (CBF) was possible. With the introduction of integrated, hybrid magnetic resonance (MR)-PET scanners, such a comparison becomes feasible. This study presents results of CBF measurements recorded simultaneously with [(15)O]water and ASL. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of magnetic resonance imaging : JMRI

دوره 40 3  شماره 

صفحات  -

تاریخ انتشار 2014