Relationship of hepatic functional parameters with changes of functional liver volume using technetium-99m galactosyl serum albumin scintigraphy in patients undergoing preoperative portal vein embolization: a follow-up report.
نویسندگان
چکیده
BACKGROUND To identify predictors of changes in functional hepatic volumes after portal vein embolization (PVE) before hepatectomy, we examined the relationship between hepatic functional parameters and changes in functional volume of the embolized and non-embolized liver based on a previous volumetric analysis. MATERIAL AND METHODS Subjects were 24 patients who underwent PVE, which was performed through the trans-ileocolic vein (n = 4) or by percutaneous transhepatic puncture (n = 20). The RI liver volume parameter was measured by liver scintigraphy with technetium-(99m) galactosyl human serum albumin ((99m)Tc-GSA). Computed tomography (CT) volume parameter was also measured. RESULTS Significant atrophy of the embolized liver and hypertrophy of the non-embolized liver (change of 72 ± 108 cm(3) and 111 ± 91 cm(3), respectively) (change of 7.8%) was observed after PVE. The change in these RI volume parameters (change of 173 ± 175 cm(3) and 145 ± 137 cm(3) , respectively) (16.5%) was significantly greater than CT volume parameters (P < 0.01). CT vol and RI vol in the embolized and non-embolized liver were well correlated (r = 0.75 and 0.69, respectively). However, the correlation between CT and RI volume parameters in the embolized and non-embolized liver after PVE was very weak (r = 0.17 and 0.03, respectively). Only alkaline phosphatase level correlated negatively with atrophic CT volume parameter of the embolized liver (r = -0.455, P < 0.05). When compared with CT volume parameter, more parameters were significantly correlated with changes of RI volume parameter in the embolized liver: pre-PVE pressure; ICGR15; and serum levels of hyaluronate, total bilirubin, albumin, and alkaline phosphatase. Only platelet count was significantly correlated with hypertrophy of the non-embolized liver. CONCLUSION RI volume parameter might more accurately reflect functional changes in the embolized liver and non-embolized liver than CT volume parameter. Correlated parameters might allow us to predict the functional effect of PVE.
منابع مشابه
Usefulness of examining hepatic functional volume using technetium-99m galactosyl serum albumin scintigraphy in hepatocellular carcinoma.
OBJECTIVES The aim of the study was to clarify the clinical significance of single-photon emission computed tomography/computed tomography (SPECT/CT) imaging in terms of technetium-99m galactosyl human serum albumin (99mTc-GSA) scintigraphy. To this end, we examined the relationship using data from surgical records of 67 patients with hepatocellular carcinoma who underwent hepatectomy. MATERI...
متن کاملCourse before and after percutaneous transhepatic portal vein embolization of a patient with cholangiocarcinoma monitored by scintigraphy with Tc-99m galactosyl human serum albumin.
Percutaneous transhepatic portal vein embolization (PTPE) causes atrophy of the embolized lobe and compensatory hypertrophy of the nonembolized lobe, and improves the safety of hepatectomy. We report a patient with cholangiocarcinoma who underwent embolization of both anterior and posterior branches of the right portal vein before hepatectomy. Scintigraphy with Tc-99m galactosyl human serum alb...
متن کاملNuclear imaging techniques for the assessment of hepatic function in liver surgery and transplantation.
This review describes the application of 2 nuclear imaging techniques for assessment of hepatic function in the setting of liver surgery and transplantation. The biochemical and technical background, as well as the clinical applications, of (99m)Tc-labeled diethylenetriaminepentaacetic acid galactosyl human serum albumin (GSA) scintigraphy and hepatobiliary scintigraphy (HBS) with (99m)Tc-label...
متن کاملEvaluation of persistence of ductus venosus with tc-99m DTPA galactosyl human serum albumin liver scintigraphy and I-123 iodoamphetamine per-rectal portal scintigraphy.
Tc-99m DTPA galactosyl human serum albumin (Tc-99m GSA) hepatic scintigraphy was performed in two patients with patent ductus venosus before and after operation. To evaluate the portosystemic shunt flow, per-rectal portal scintigraphy with I-123 N-isopropyl-p-iodoamphetamine (IMP) was undergone in the same period. The portosystemic shunt indices (PSS index) were decreased from 67.9% to 7.3% in ...
متن کاملClinical need for both scintigraphy with technetium-99m GSA and per-rectal portal scintigraphy in some patients with chronic liver disease.
Scintigraphy with 99mTc-diethylenetriaminepentaacetate with galactosyl human serum albumin (99mTc-GSA) and per-rectal portal scintigraphy are useful for evaluating hepatic functional reserve and portal circulation, respectively. We did the procedures simultaneously in some patients to examine the relationship between hepatic functional reserve and portal circulation in chronic liver disease. Sc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of surgical research
دوره 164 2 شماره
صفحات -
تاریخ انتشار 2010