Plastic Design and Testing of Light-gauge Steel Plate Shear Walls
نویسندگان
چکیده
In this paper, the strip model developed by others and implemented in a Canadian Standard to model steel plate shear walls (SPSW) is used to develop, investigate, and quantify, through plastic analysis, the various possible collapse mechanisms of SPSW. Comparisons of experimentally obtained ultimate strengths of steel plate shear walls and those predicted by plastic analysis are given and reasonable agreement is observed. Modifications are proposed to a section of an existing codified procedure for the design of steel plate walls which is shown could lead to designs with less-than-expected ultimate strength. In addition to the above, this paper also describes the results of an experimental study to determine the feasibility of light-gauge SPSW for use in the seismic retrofit of buildings. Three specimens were constructed and tested under quasi-static loading, one using a corrugated infill and epoxy connection to the surrounding frame, one using a flat infill with an epoxy connection to the surrounding frame, and one using a flat infill with a welded connection to the frame. The flat infill with the welded connection reached a ductility ratio of 12 and had substantially superior behavior when compared to the other two specimens.
منابع مشابه
Experimental Investigation of Light-Gauge Steel Plate Shear Walls
This paper describes the prototype design, specimen design, experimental setup, and experimental results of three light-gauge steel plate shear wall concepts. Prototype light-gauge steel plate shear walls are designed as seismic retrofits for a hospital structure in an area of high seismicity, and emphasis is placed on minimizing their impact on the existing framing. Three single-story test spe...
متن کاملCyclic Testing of Light-Gauge Steel Plate Shear Walls
This paper describes the prototype design, specimen design, experimental set-up, and experimental results of tests on three light-gauge steel plate shear wall (SPSW) concepts. Prototype light-gauge steel plate shear walls are designed as seismic retrofits for a hospital structure in an area of high seismicity and emphasis is placed on minimizing their impact on the existing framing. Three singl...
متن کاملPlastic Analysis and Design of Steel Plate Shear Walls (2001-2002)
A revised procedure for the design of steel plate shear walls is proposed. In this procedure, the thickness of the infill plate is found using equations that are derived from plastic analysis of the strip model, which is widely accepted for the representation of steel plate shear walls. Equations are derived from a basic steel plate shear wall configuration but are shown to be conservative for ...
متن کاملPlastic Analysis and Design of Steel Plate Shear Walls
A revised procedure for the design of steel plate shear walls is proposed. In this procedure the thickness of the infill plate is found using equations that are derived from the plastic analysis of the strip model, which is an accepted model for the representation of steel plate shear walls. Comparisons of experimentally obtained ultimate strengths of steel plate shear walls and those predicted...
متن کاملCase Study on the Impact of Horizontal Boundary Elements Design on Seismic Behavior of Steel Plate Shear Walls
Acase studywas conducted to investigate the seismic behavior of steel plate shear walls having boundary elements designed by two different philosophies. The first design approach does not guarantee that formation of in-span plastic hinges on horizontal boundary elements (HBEs) will be prevented, whereas the second approach guarantees that plastic hinges can only occur at the ends of HBEs. Pusho...
متن کامل