Determination of the gamma-ray effective dose from different cylindrical radioactive solution sources in a biological tissue by using Monte Carlo calculations

نویسندگان

  • M. A. MISDAQ
  • A. MERZOUKi
چکیده

A new method was developed based on calculating the ahsorption coefficients, selfabsorption coefficients and transmission coefîlcients of the gamma-photons emitted by different radioisotopes for evaluating gamma dose equivalent rates, at 1 meter from varions cylindrical radioactive solution sources utilized in medicine, in a biological tissue. Resnlts obtained were compared with data given in literatnre. The influence of the radioisotope half-life and gamma-photon energy and number of photons per disintegration on the gamma dose equivalent rate, effective dose and threshold initial activity of the considered solution sources was studied. ABSTRACT

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetry of 188Re and 186Re sources based on Monte Carlo calculations for endovascular brachytherapy after balloon angioplasty

Background: Recent pre-clinical and clinical studies indicate that irradiation in the dose range of 15 to 30 Gy can reduce rate of restenosis in patients who have undergone an angioplasty. The use of filled balloon with radioactive solution was proposed as one of the possible intravascular irradiation techniques. Materials and Methods: The Monte Carlo N-particle Transport Code (MCNP4b) was used...

متن کامل

Absorbed Dose Assessment from Short-Lived Radionuclides of Radon (222Rn) Decay Chain in Lung Tissue: A Monte Carlo Study

Introduction: Internal exposure to radon gas progeny can lead to serious biologic damages to the lung tissue. The aim of this study was to evaluate the absorbed dose by lung tissue due to the exposure from short-lived radioactive products of radon (222Rn) decay using Monte Carlo simulation. Material and Methods: A lung equivalent p...

متن کامل

Determination of virtual point for HPGe detector at various gamma rays energies by simulation and experimental methods

High Purity Germanium detectors (HPGe) are subdivisions of semiconductor detectors which are widely used in nuclear technology from space industry to nuclear medicine, due to their high resolution, low dead time, unlimited size and compatibility with a variety of environments. The( absolute and intrinsic) efficiency of the HPGe detector, which depends on the geometry of the source-detector syst...

متن کامل

Comparison of dosimetry parameters of two commercially available Iodine brachytherapy seeds using Monte Carlo calculations

Background: Iodine brachytherapy sources with low photon energies have been widely used in treating cancerous tumors. Dosimetric parameters of brachytherapy sources should be determined according to AAPM TG-43U1 recommendations before clinical use. Monte Carlo codes are reliable tools in calculation of these parameters for brachytherapy sources. Materials and Methods: Dosimetric param...

متن کامل

Radial dose functions of GZP6 intracavitary brachytherapy 60Co sources: treatment planning system versus Monte Carlo calculations

Background: The Monte Carlo (MC) method is not only used for dose calculations around brachytherapy sources but also for benchmarking treatment planning systems (TPS) calculations. Materials and Methods: Three 60Co sources of GZP6 brachytherapy unit were simulated using MCNP4C MC Code. The radial dose functions were calculated by MC method and GZP6 TPS and were compared. Results: There was a go...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005