Determination of gentamicin in different matrices by a new sensitive high-performance liquid chromatography-mass spectrometric method.
نویسندگان
چکیده
OBJECTIVES The aim of this work was to develop and validate an HPLC method for gentamicin quantification in different types of biological samples such as animal tissues and cellular material and also in pharmaceuticals. METHODS Poly(lactide-co-glycolide) microparticles (MP) of gentamicin (PLGA 502H MP), THP-1 cells, and plasma and tissue samples of mice treated with the antibiotic either free or loaded into PLGA 502H MP were processed by a simple preparation procedure, subjected to chromatography on a reversed-phase column and measured by mass spectrometry detection. The developed method was compared with bioassay and fluorimetric assay methods previously used for gentamicin determination. RESULTS The HPLC method was linear over the ranges 40-800 ng/mL and 0.1-100 microg/mL and showed good accuracy (average accuracy < 5.59%) and reproducibility (CV < 6.13%). Encapsulation of gentamicin in PLGA 502H MP was determined by the three methods. Good correlation was observed between bioassay (reference method) and HPLC. Extra- and intracellular in vitro antibiotic accumulation was determined by bioassay and chromatography. Both methods gave similar extracellular concentrations but the HPLC-MS technique demonstrated an improved accuracy (5.59% versus 14%) and precision (6.13% versus 15%) compared with bioassay. However, only the HPLC-MS method was sensitive enough to detect the drug, intracellularly and in tissues. CONCLUSIONS All these data favour the use of chromatography-mass spectrometry as a versatile technique not only suitable for gentamicin quantification loaded in drug delivery systems, but also sensitive and specific enough for in vivo and intracellular studies.
منابع مشابه
Comparative Pharmacokinetics of Berberine, Palmatine and Jatrorrhizine in Rat Plasma after Oral Administration of Rhizoma coptidis and Zuojinwan Using Liquid Chromatography-Tandem Mass Spectrometry
A selective and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the determination of berberine, palmatine and jatrorrhizine in rat plasma. Target compounds, together with the internal standard (metronidazole), were extracted from rat plasma samples by protein precipitation with acetonitrile-methanol (1:2, v/v). Chromatography was carried out using a ...
متن کاملDevelopment and Application of a Validated Liquid Chromatography-Mass Spectrometry Method for the Determination of Dexchlorpheniramine Maleate in Human Plasma
A convenient liquid chromatographic-single Quadrupole mass spectrometric (LC-MS) method was developed and validated for dexchlorpheniramine maleate (INN name: chlorphenamine) determination in human plasma. The need for just a single liquid-liquid extraction with ethyl acetate and being highly sensitive were the advantages of this method. The linearity was also excellent over the range of 1...
متن کاملA simple, sensitive and rapid isocratic reversed-phase high-performance liquid chromatography method for determination and stability study of curcumin in pharmaceutical samples
Objective: This study was designed to develop and validate a new reversed-phase high-performance liquid chromatography (RP-HPLC) method based on Q2 (R1) International Conference on Harmonization (ICH) guideline for determination of curcumin in pharmaceutical samples. Materials and Methods: The HPLC instrument method was optimized with isocratic elution with acetonitrile: ammonium acetate (45:55...
متن کاملComparative Pharmacokinetics of Berberine, Palmatine and Jatrorrhizine in Rat Plasma after Oral Administration of Rhizoma coptidis and Zuojinwan Using Liquid Chromatography-Tandem Mass Spectrometry
A selective and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the determination of berberine, palmatine and jatrorrhizine in rat plasma. Target compounds, together with the internal standard (metronidazole), were extracted from rat plasma samples by protein precipitation with acetonitrile-methanol (1:2, v/v). Chromatography was carried out using a ...
متن کاملHigh Performance Liquid Chromatography Coupled with Pre-column Derivatization for Determination of Oxidized Glutathione Level in Rats Exposed to Paraquat
Glutathione (GSH) is one of the most important antioxidants that plays an essential role in detoxification of reactive oxygen species (ROS) which oxidizes to glutathione disulfide (GSSG). Paraquat (PQ), awidely used herbicide, causes pulmonary injury with the productionof ROS. Excessive ROS accumulation as a consequence of PQ exposure are frequently targeted by GSH thereby oxidative stress lead...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of antimicrobial chemotherapy
دوره 58 3 شماره
صفحات -
تاریخ انتشار 2006