Fire Safety Requirements on Lift System for Evacuation in Supertall Buildings

نویسندگان

  • N. Cai
  • W. K. Chow
چکیده

Fire safety requirements on lift system used for evacuation in supertall buildings were discussed in this paper. Designs for fire and smoke protection for lift systems for evacuation were reviewed. Lifts are not yet designed to be used by most of the occupants in fire. Two major safety concerns were identified on the hazards due to smoke spread to the lift shafts and lobby; and the fire resisting construction required under big fires. Fire safety protection for evacuation is not demonstrated to be adequate for supertall buildings. Key issues and problems need to be addressed were discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Factors Influencing Failure Emergency Evacuation in Work Environments during Fire

One of the necessary measures of saving human life in emergency situations, such as fires, is the safe and swift evacuation of people. The prerequisites for this are to anticipate, identify, and eliminate factors preventing people from leaving buildings in a timely and safe manner while moving them to a safe place [1]. The occurrence of errors caused by engineering, design, human, and psycholog...

متن کامل

Escaping with your life

Of the many horrors of September 11, 2001, the sight of people falling and jumping to their deaths from the Towers of the World Trade Center will not be soon forgotten by anyone watching. The sight brutally expressed the desperation of those trapped above the raging fires, unable or unwilling to descend through the wounded structures. Even in light of the eventual collapse of the structures, th...

متن کامل

Enhancement of Fire Safety of an Existing Green Building due to Natural Ventilation

In recent years, natural ventilation technology is extensively used in order to improve indoor environment quality and reduce power consumption of air-conditioning systems in green buildings. However, the effect of natural ventilation on fires needs to be evaluated carefully, and how to make these energy-saving buildings safe is a topic worth studying. This study uses Fire Dynamics Simulator on...

متن کامل

Simulation of Metro Train Fire in an Underground Station of Tehran Metro Line 7

In this research a fire scenario was simulated in one of the stations of the line 7 of Tehran's subway system. The Line 7 is under construction and the ventilation system is under design. Fire was set for a stopping metro train at the platform of the station. A 160 meter length eight-car metro train with the forth wagon on the fire was studied. The heat release rate is based on a quadratic f...

متن کامل

DDDAS for Fire and Agent Evacuation Modeling of the Rhode Island Nightclub Fire

A Dynamic Data Driven Application System (DDDAS) was created to study interaction between fire and agent models during a fire evacuation. The analysis from that research can be used to validate proposed ideas in evacuation and building designs to ensure safety of buildings given various agent behaviors. Two separate models were used to simulate the components of the emergency situation: fire an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011