Influence of cervical preflaring on determination of apical file size in mandibular molars: SEM analysis.

نویسندگان

  • Marcia da Silva Schmitz
  • Roberto Santos
  • Alexandre Capelli
  • Marcos Jacobovitz
  • Júlio César Emboava Spanó
  • Jesus Djalma Pécora
چکیده

This study investigated the influence of cervical preflaring with different rotary instruments on determination of the initial apical file (IAF) in mesiobuccal roots of mandibular molars. Fifty human mandibular molars whose mesial roots presented two clearly separated apical foramens (mesiobuccal and mesiolingual) were used. After standard access opening and removal of pulp tissue, the working length (WL) was determined at 1 mm short of the root apex. Five groups (n=10) were formed at random, according to the type of instrument used for cervical preflaring. In group 1, the size of the IAF was determined without preflaring of the cervical and middle root canal thirds. In groups 2 to 5, preflaring was performed with Gates-Glidden drills, ProTaper instruments, EndoFlare instruments and LA Axxes burs, respectively. Canals were sized manually with K-files, starting with size 08 K-files, inserted passively up to the WL. File sizes were increased until a binding sensation was felt at the WL and the size of the file was recorded. The instrument corresponding to the IAF was fixed into the canal at the WL with methylcyanoacrylate. The teeth were then sectioned transversally 1 mm short of the apex, with the IAF in position. Cross-sections of the WL region were examined under scanning electron microscopy and the discrepancies between canal diameter and the diameter of IAF were calculated using the tool "rule" (FEG) of the microscope's proprietary software. The measurements (microm) were analyzed statistically by Kruskal-Wallis and Dunn's tests at 5% significance level. There were statistically significant differences among the groups (p<0.05). The non-flared group had the greatest discrepancy (125.30 +/- 51.54) and differed significantly from all flared groups (p<0.05). Cervical preflaring with LA Axxess burs produced the least discrepancies (55.10 +/- 48.31), followed by EndoFlare instruments (68.20 +/- 42.44), Gattes Glidden drills (68.90 +/- 42.46) and ProTaper files (77.40 +/- 73.19). However, no significant differences (p>0.05) were found among the rotary instruments. In conclusion, cervical preflaring improved IAF fitting to the canals at the WL in mesiobuccal roots of maxillary first molars. The rotary instruments evaluated in this study did not differ from each other regarding the discrepancies produced between the IAF size and canal diameter at the WL.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of cervical preflaring on determination of apical file size in maxillary molars: SEM analysis.

The purpose of this study was to investigate the influence of cervical preflaring on determination of the initial apical file in mesiobuccal roots of maxillary molars. Fifty first molars with degree of curvature of the mesiobuccal root between 10 degrees and 15 degrees were utilized. After standard access opening and removal of pulp tissue, the working length (WL) was determined at 1 mm from th...

متن کامل

An in vivo study to determine the effects of early preflaring on the working length in curved mesial canals of mandibular molars.

AIM To evaluate the effects of a preflaring method on the determination of working length in the curved mesial canals of mandibular molars. MATERIALS AND METHODS Ninety mandibular molars with apical curvature of 30 to 40° were selected and randomly divided into two groups; each containing 45 teeth. In the first group, the initial instrumentation was performed with preflaring on the mesiobucca...

متن کامل

Influence of cervical preflaring on apical file size determination in maxillary lateral incisors.

The purpose of this study was to investigate the influence of cervical preflaring on determination of the initial apical file in maxillary lateral incisors. Forty human lateral incisors with complete root formation were used. After standard access cavities, a size 06 K-file was inserted into each canal until the apical foramen was reached. The WL (WL) was set 1 mm short of the apical foramen. F...

متن کامل

Crown-down preflaring in the determination of the first apical file.

In this study, scanning electron microscopy (SEM) was used to evaluate the adaptation of the first apical file after preflaring in mesiobuccal (MB) and mesiolingual (ML) canals of mandibular molars considering the tactile sensibility as a reference. The mesial canals (n = 22) of human mandibular molar teeth were used, and the first instrument to bind to the working length was determined after p...

متن کامل

Influence of cervical preflaring on determination of apical file size in maxillary premolars: SEM analysis.

The purpose of this study was to investigate the influence of cervical preflaring on the determination of the first file that binds at working length (WL) in buccal roots of maxillary premolars. Five groups (n=10) were formed at random and, after standard access cavities, the WL was determined 1 mm short from the apex. In group 1, the initial apical file was inserted without preflaring of cervi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brazilian dental journal

دوره 19 3  شماره 

صفحات  -

تاریخ انتشار 2008