Pharmacokinetics of [18F]trovafloxacin in healthy human subjects studied with positron emission tomography.

نویسندگان

  • A J Fischman
  • J W Babich
  • A A Bonab
  • N M Alpert
  • J Vincent
  • R J Callahan
  • J A Correia
  • R H Rubin
چکیده

Tissue pharmacokinetics of trovafloxacin, a new broad-spectrum fluoroquinolone antimicrobial agent, were measured by positron emission tomography (PET) with [18F]trovafloxacin in 16 healthy volunteers (12 men and 4 women). Each subject received a single oral dose of trovafloxacin (200 mg) daily beginning 5 to 8 days before the PET measurements. Approximately 2 h after the final oral dose, the subject was positioned in the gantry of the PET camera, and 1 h later 10 to 20 mCi of [18F]trovafloxacin was infused intravenously over 1 to 2 min. Serial PET images and blood samples were collected for 6 to 8 h, starting at the initiation of the infusion. Drug concentrations were expressed as the percentage of injected dose per gram, and absolute concentrations were estimated by assuming complete absorption of the final oral dose. In most tissues, there was rapid accumulation of the radiolabeled drug, with high levels achieved within 10 min after tracer infusion. Peak concentrations of more than five times the MIC at which 90% of the isolates are inhibited (MIC90) for most members of Enterobacteriaceae and anaerobes (>10-fold for most organisms) were achieved in virtually all tissues, and the concentrations remained above this level for more than 6 to 8 h. Particularly high peak concentrations (micrograms per gram; mean +/- standard error of the mean [SEM]) were achieved in the liver (35.06 +/- 5.89), pancreas (32.36 +/- 20. 18), kidney (27.20 +/- 10.68), lung (22.51 +/- 7.11), and spleen (21. 77 +/- 11.33). Plateau concentrations (measured at 2 to 8 h; micrograms per gram; mean +/- SEM) were 3.25 +/- 0.43 in the myocardium, 7.23 +/- 0.95 in the lung, 11.29 +/- 0.75 in the liver, 9.50 +/- 2.72 in the pancreas, 4.74 +/- 0.54 in the spleen, 1.32 +/- 0.09 in the bowel, 4.42 +/- 0.32 in the kidney, 1.51 +/- 0.15 in the bone, 2.46 +/- 0.17 in the muscle, 4.94 +/- 1.17 in the prostate, and 3.27 +/- 0.49 in the uterus. In the brain, the concentrations (peak, approximately 2.63 +/- 1.49 microg/g; plateau, approximately 0.91 +/- 0.15 microg/g) exceeded the MIC90s for such common causes of central nervous system infections as Streptococcus pneumoniae (MIC90, <0.2 microg/ml), Neisseria meningitidis (MIC90, <0.008 microg/ml), and Haemophilus influenzae (MIC90, <0.03 microg/ml). These PET results suggest that trovafloxacin will be useful in the treatment of a broad range of infections at diverse anatomic sites.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnostic Accuracy of Positron Emission Mammography with 18F-fluorodeoxyglucose in Breast Cancer Tumor of Less than 20 mm in Size

Objective(s): To investigate the diagnostic accuracy of positron emission mammography (PEM) and positron emission tomography/computed tomography (PET/CT) for small breast tumors of less than 20 mm in size.Methods: The study was conducted on a total of 100 subjects (i.e., 50 patients with pathologically proven breast cancer and 50 normal cases of medical screening). The total number of tumors wa...

متن کامل

Diagnostic Performance and Safety of Positron Emission Tomography Using 18F-Fluciclovine in Patients with Clinically Suspected High- or Low-grade Gliomas: A Multicenter Phase IIb Trial

Objective(s): The study objective was to assess the diagnostic performance of positron emission tomography (PET) for gliomas using the novel tracer 18F-fluciclovine (anti-[18F]FACBC) and to evaluate the safety of this tracer in patients with clinically suspected gliomas.Methods: Anti-[18F]FACBC was administered to 40 patients with clinically suspected high- or low-grade gliomas, followed by PET...

متن کامل

Calculation of Positron Distribution in the Presence of a Uniform Magnetic Field for the Improvement of Positron Emission Tomography (PET) Imaging Using GEANT4 Toolkit

Introduction Range and diffusion of positron-emitting radiopharmaceuticals are important parameters for image resolution in positron emission tomography (PET). In this study, GEANT4 toolkit was applied to study positron diffusion in soft tissues with and without a magnetic field for six commonly used isotopes in PET imaging including 11C, 13N, 15O, 18F, 68Ga, and 82Rb. Materials and Methods GEA...

متن کامل

Background-Based Delineation of Internal Tumor Volumes on Static Positron Emission Tomography in a Phantom Study

Objective(s): Considering the fact that the standardized uptake value (SUV) of a normal lung tissue is expressed as x±SD, x+3×SD could be considered as the threshold value to outline the internal tumor volume (ITV) of a lung neoplasm. Methods: Three hollow models were filled with 55.0 kBq/mL fluorine18- fluorodeoxyglucose (18F-FDG) to represent tumors. The models were fixed to a barrel filled w...

متن کامل

Imaging Cellular Proliferation in Prostate Cancer with Positron Emission Tomography

Prostate cancer remains a major public health problem worldwide. Imaging plays an important role in the assessment of disease at all its clinical phases, including staging, restaging after definitive therapy, evaluation of therapy response, and prognostication. Positron emission tomography with a number of biologically targeted radiotracers has been demonstrated to have potential diagnostic and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Antimicrobial agents and chemotherapy

دوره 42 8  شماره 

صفحات  -

تاریخ انتشار 1998