Reliability of echocardiographic assessment of left ventricular structure and function: the PRESERVE study. Prospective Randomized Study Evaluating Regression of Ventricular Enlargement.
نویسندگان
چکیده
OBJECTIVES The study was done to evaluate reliability of echocardiographic left ventricular (LV) mass. BACKGROUND Echocardiographic estimation of LV mass is affected by several sources of variability. METHODS We assessed intrapatient reliability of LV mass measurements in 183 hypertensive patients (68% men, 65 +/- 9 years) enrolled in the Prospective Randomized Enalapril Study Evaluating Regression of Ventricular Enlargement (PRESERVE) trial after a screening echocardiogram (ECHO) showed LV hypertrophy. A second ECHO was repeated at randomization (45 +/- 25 days later). Two-dimensional (2D)-guided M-mode or 2D linear measurements of LV cavity and wall dimensions were verified by one experienced reader. RESULTS Mean LV mass was similar at first and second ECHO (243 +/- 53 vs. 241 +/- 54 g) and showed high reliability as estimated by intraclass correlation coefficient (RHO) = 0.93. Within-patient 5th, 10th, 90th and 95th percentiles of between-study difference in LV mass were -32 g, -28 g, +25 g and +35 g. Mean LV mass fell less from the first to the second ECHO than expected from a formula to predict regression to the mean (2 +/- 19 vs. 17 +/- 12 g, p < 0.001). Reliability was also high for LV internal diameter (RHO = 0.87), septal (RHO = 0.85) and posterior wall thickness (RHO = 0.83). Substantial or moderate reliability was observed for measures of LV systolic function and diastolic filling (RHO from 0.71 to 0.57). CONCLUSIONS Left ventricular mass had high reliability and little regression to the mean; between-study LV mass change of +/-35 g or +/-17 g had > or = 95% or > or = 80% likelihood of being true change.
منابع مشابه
بررسی اثر کاهش حجم بر روی پارامترهای دیاستولیک اکو کاردیوگرافی در بیماران همودیالیزی
Background: Cardiovascular problems including arterial hypertension, coronary artery diseases, congestive heart failure are prevalent among chronic hemodialyzed patients. Ultrafiltration of hemodialyzed patient's serum, which culminating in intravascular volume reduction, is frequently used during hemodialysis. One of the restrictions of the echocardiographic evaluation of the diastolic heart f...
متن کاملComparison of Cardiac Function in Young Patients with Thalassemia Intermedia and Healthy Individuals Using Echocardiography Method
Background: Cardiac dysfunction due to chronic anemia and hemosiderosis are the major causes of death among patients with thalassemia intermedia. This study was performed to compare the cardiac function in thalassemia intermedia patients with normal subjects by means of echocardiography. Materials and Methods: This was a case-control study performed on 22 patients affected by thalassemia int...
متن کاملEvaluation of Cardiac Function in Patients with Thalassemia Intermedia
Abstract Background Thalassemia intermedia is a variety of beta thalassemia which shows clinical symptoms somewhere between asymptomatic carriers and thalassemia major. Cardiac dysfunctions due to chronic anemia and hemosiderosis are the major causes of death in these patients. The purpose of this study is to evaluate cardiac function in these patients by echocardiography. Materials and Met...
متن کاملEvaluation of Advanced Echocardiographic Parameters of Right Ventricular in Patients with Pulmonary Hypertension
Background and Objective: Pulmonary hypertension is an increase in blood pressure of the pulmonary artery which leads to right ventricular dysfunction. Therefore, the present study aimed to compare echocardiographic parameters in the study of right ventricular failure in patients with pulmonary hypertension. Materials and Methods: In the present descriptive cross-sectional study, data were col...
متن کاملReference values of M-mode echocardiographic parameters and indices in conscious Labrador Retriever dogs
Breed-wise standard echocardiographic values in dogs have been reported as there is variation in body and chest conformation which limits the application of data of one breed for other breed. Labrador Retrievers being originated from hunting dogs, might have different echocardiographic values from standard normal range of other dog breeds. So, the present study was aimed to determine the M-mode...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American College of Cardiology
دوره 34 5 شماره
صفحات -
تاریخ انتشار 1999