Comparison of 2 modified methods for the active removal of silicone oil with a 23-gauge transconjunctival vitrectomy system

نویسندگان

  • Chengqun Ju
  • Jianqiao Li
  • Fang Zhou
  • Qi Song
  • Xinyi Wu
  • Chao Huang
  • Shanshan Li
  • Helei Wang
چکیده

To report and compare 2 modified approaches for the active removal of silicone oil (ROSO) with a 23-gauge transconjunctival vitrectomy system.This prospective single blinded study was conducted from January 2015 to December 2016. Eighty-nine eyes of 86 patients who underwent silicone oil removal were enrolled. Patients were randomly divided into either group A or B. In group A, the fluid-air exchange tube was connected to a 1 mL syringe with the plunger removed and the tip was dilated with a hemostat so that it fit into the cap of the 23-gauge cannula to form a seal for oil drainage. In group B, the tip of the syringe was closely attached to the cap of the 23-gauge cannula by a tube adaptor, which was salvaged from a used silicone oil inject and aspirate pack and sterilized. Main outcome measures were time required for silicone oil removal, silicone oil residual, intraoperative and postoperative complications including hypotony, bleeding, and retinal redetachment.The mean time required was 6.08 ± 0.31 minutes and 6.11 ± 0.31 minutes for groups A and B, respectively. No silicone oil residual, severe hypotony, recurrence of retinal detachment, or impairment of visual acuity were observed in either group. Conjunctival injection and hyperemia were slightly more severe in group A, but spontaneously resolved in 2 to 3 days.Both methods described in this paper were demonstrated to be safe, effective, and cost-effective for the ROSO. The syringe dilation method caused more severe conjuntival irritation, thus we suggest using the tube adaptor method for hospitals equipped with cold sterilization equipment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Active Silicone Oil Removal with a Transconjunctival Sutureless System: Is the 23-Gauge System Safe and Effective?

OBJECTIVES To evaluate the safety and efficacy of active silicone oil removal with a 23-gauge (G) transconjunctival sutureless system. MATERIALS AND METHODS One hundred sixteen eyes of 113 patients who had previous retinal detachment surgery with pars plana vitrectomy and silicone oil injection surgery, and underwent silicone oil removal surgery with 23-G transconjonctival sutureless techniqu...

متن کامل

Passive removal of silicone oil through 23 gauge transconjunctival sutureless vitrectomy system

OBJECTIVE To study the outcomes of passive removal of silicone oil by 23 Gauge Transconjunctival Sutureless Vitrectomy System. METHODS This prospective, consecutive case series study was conducted at Ophthalmology Department Unit I, Dow University of Health Sciences, Civil Hospital Karachi from January 2011 to December 2014. Only psuedophakic eyes with silicone oil temponade were selected. Ma...

متن کامل

Passive Removal of Silicone Oil with Temporal Head Position through Two 23-Gauge Cannulas

Purpose. To report a new approach for removal of silicone oil. Methods. All surgeries were performed using 23-gauge vitrectomy system with two transconjunctival sutureless cannulas. At the beginning, most of the silicone oil was removed by traditional microinvasive vitrectomy system through inferior-temporal cannula. Then, the blood transfusion tube is removed from the inferior-temporal cannula...

متن کامل

Influence of silicone oil tamponade on self-sealing sclerotomy using 25-gauge transconjunctival sutureless vitrectomy: a retrospective comparative study

BACKGROUND Characteristic complications have been reported for transconjunctival sutureless vitrectomy, such as postoperative sclerotomy leakage and postoperative hypotony. Particular attention to sclerotomy closure is required in cases of silicone oil tamponade, because postoperative supplementation of silicone oil implies reoperation, whereas postoperative supplement of gas is comparatively e...

متن کامل

Investigation of postoperative intraocular pressure in cases of silicone oil removal using 25-gauge transconjunctival sutureless vitrectomy with oblique incisions

BACKGROUND The purpose of this study was to investigate postoperative intraocular pressure (IOP) in cases of silicone oil (SO) removal when using 25-gauge transconjunctival sutureless vitrectomy (TSV) with oblique incisions. METHODS We enrolled ten consecutive eyes with SO removal (SO group) and eleven consecutive eyes with idiopathic epiretinal membrane (ERM) as the initial vitrectomy (ERM g...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 96  شماره 

صفحات  -

تاریخ انتشار 2017