New bi-sign aspheric IOL and its application.
نویسنده
چکیده
PURPOSE To present a bi-sign aspheric intraocular lens (IOL) and make theoretical comparisons with spherical and one-sign aspheric IOLs for retinal image quality in mesopic conditions and intermediate image capability in photopic conditions. METHODS Using ray-tracing in pseudophakic eye models, retinal image quality in terms of modulation transfer function was analyzed between the bi-sign aspheric and three types of one-sign aspheric IOLs and the spherical IOL for the range of corneal asphericities and different lens misalignments at 5 mm pupil diameter; comparison is made with the spherical IOL at defocus conditions characterized by negative refractive errors at 3 mm pupil diameter. RESULTS Retinal image quality of the bi-sign aspheric lens was equal to or exceeded the one-sign aspheric and spherical IOLs in the majority of anterior cornea asphericities and lens misalignments within the spatial frequencies of 6 to 15 c/deg. Intermediate image capability of the bi-sign aspheric exceeded the spherical IOL. CONCLUSIONS A new bi-sign aspheric lens produces regions of opposite spherical aberrations in the eye model with pupil diameters above 3 mm to balance out aberrations within the lens itself in addition to compensating corneal aberration as with a one-sign aspheric lens. This allows reduction in the variability of the retinal image quality at different anterior cornea asphericities and lens misalignments, when compared with a one-sign aspheric and spherical lens. The bi-sign aspheric produces positive longitudinal spherical aberration in the eye model within 3 mm pupil diameter that improves intermediate image capability when compared with the spherical IOL.
منابع مشابه
Performance of presbyopia-correcting intraocular lenses in distance optical bench tests.
PURPOSE To compare the optical performance of 6 presbyopia-correcting intraocular lenses (IOLs) of different designs (accommodating or multifocal and aspheric or spheric). SETTING Alcon Laboratories, Inc., Fort Worth, Texas, USA. METHODS The optical performance of 6 IOLs were compared using modulation transfer function (MTF) and the United States Air Force 1951 Resolution Target (AFT) testi...
متن کاملDesign of isoplanatic aspheric monofocal intraocular lenses.
A new and complete methodology of monofocal intraocular lens (IOL) design is presented aiming at isoplanatism, i.e. IOLs that provide the eye with optimized optical quality over a wide field of view (typically in a range of ten degrees). The methodology uses a merit function considering dimensional and biomechanical constraints, and a geometrical optical quality metric that is evaluated simulta...
متن کاملThe efficiency of aspheric intraocular lens according to biometric measurements
PURPOSE To analyze internal spherical aberration in pseudophakic eyes that underwent aspheric intraocular lens (IOL) implantation, and to investigate the relationships between biometric data and the effectiveness of aspheric IOL implantation. METHODS This retrospective study included 40 eyes of 40 patients who underwent implantation of an IOL having a negative spherical aberration of -0.20 μm...
متن کاملIntraocular Lens Multifocality Combined with the Compensation for Corneal Spherical Aberration: A New Concept of Presbyopia-Correcting Intraocular Lens
The outcomes of a prospective consecutive study aimed at evaluating the visual and refractive benefit after cataract surgery with the implantation of the aspheric diffractive multifocal intraocular lens (IOL) Tecnis ZMB00 (Abbott Medical Optics) are reported. A total of 31 eyes of 19 patients (age range, 40 to 81 years) underwent phacoemulsification surgery with implantation of this aspheric mu...
متن کاملDesign and qualification of a diffractive trifocal optical profile for intraocular lenses.
PURPOSE To theoretically and experimentally assess a new aspheric diffractive trifocal intraocular lens (IOL). SETTING Centre Spatial de Liège, Liège, Belgium. DESIGN Evaluation of diagnostic test or technology. METHODS The theoretical profile of the IOL was designed using software simulation and validated by optical calculation software tools that enabled complete theoretical characteriz...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optometry and vision science : official publication of the American Academy of Optometry
دوره 89 1 شماره
صفحات -
تاریخ انتشار 2012