A Non-Iterative Balancing Method for HVAC Duct System

نویسندگان

  • Haoran Chen
  • Wenjian Cai
  • Qingguo Wang
  • Haoran CHEN
  • Wenjian CAI
  • Qingguo WANG
چکیده

Building Heating, Ventilation and Air Conditioning (HVAC) system maintain comfortable indoor environment by supplying processed air to each terminal precisely through duct system. Testing, Adjusting and Balancing (TAB) plays critical role in achieving desired air distribution. Traditional TAB method is inaccurate and inefficient due to its trailand-error natural, which forces people to pay high but expect low. Recently, it has been proposed that non-iterative approach to TAB is promising to improve performance and reduce cost. In this paper, a novel non-iterative balancing method is developed and implemented for TAB engineers to adjust dampers systematically and efficiently. Different from other TAB methods, this method is based on modeling and optimization. The mathematical model for duct system is firstly developed from its components including fan, duct segments and dampers to predict flow rates and pressures in the duct system for any damper positions. To identify the parameters in the model, flow rate measurements are taken for each terminal on real system under different damper positions. With the obtained model, optimal damper positions that gives desired air distribution are calculated by minimizing a specific objective function. To facilitate the adjusting process in real duct system, a sequential tuning instructions are generated which can help engineers to adjust dampers to their proper position using flowmeter as indicators. In this sequential tuning process, each damper only adjusts once to reach balance. Because the pressure and airflow dynamics of the duct system has been modeled, the entire TAB procedure is deterministic and non-iterative. Simulations are performed to validate the effectiveness of this method in Matlab/Simulink environment. Comparison study with existing methods shows that the proposed TAB method significantly shorten the duration of process and reduces balancing error while using easily-accessible equipment like pressure sensor and flowmeter only. It can be expected that the TAB service contractor will apply this method for advanced duct system where accurate air distribution is strictly required.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ارزیابی کارایی سیستم تهویه مطبوع یک ساختمان اداری در شهر تهران

Introduction: One of the factors influencing on indoor air quality of the buildings is performance of HVAC (heating, ventilation, and air conditioning) systems. These systems supply clean and odorless air, with temperature, humidity, and air velocity within comfort ranges for the residents. The aim of this study was to evaluate performance HVAC system in an administrative building in Tehran. .M...

متن کامل

RF propagation in an HVAC duct system: impulse response characteristics of the channel

Usually, the heating, ventilation, and air conditioning (HVAC) duct system in buildings is a complex network of hollow metal pipes of rectangular or circular cross-section which behave as multimode waveguides when driven at RF and microwave frequencies of common interest. HVAC ducts can be used as a wireless communication channel for providing high-speed network access to offices [1]. An exampl...

متن کامل

Measuring Sound Power in Ducted Heating, Ventilating, and Air-conditioning (HVAC) Systems for Use in Verifying Acoustical Prediction Methods

This paper discusses issues regarding in-situ methods of obtaining sound power at a point in a heating, ventilating and air-conditioning (HVAC) duct system. Such a method is being used as part of a larger investigation on acoustical prediction methods to allow for comparison of measured data to results from attenuation predictions of individual duct elements, such as elbows or dampers. Sound pr...

متن کامل

Multi-carrier Signal Transmission through HVAC Ducts: Experimental Results for Channel Capacity

In this paper, we report, for the first time, experimental results on channel capacity of heating, ventilation, and air-conditioning (HVAC) ducts based on multi-carrier transmission technique and measured channel frequency responses in the 2.4 GHz Industrial, Scientific, and Medical (ISM) band. Experiments using actual synthesized signals through a building HVAC duct system demonstrate the abil...

متن کامل

Numerical evaluation of the defrosting/defogging performance of HVAC system in the main product of the national vehicle platform

Due to the increasing development in various branches of the automotive industry, the need for a comfort climate in the cabin is more sensible. However, to achieve climate comfort, HVAC system consumes a considerable amount of engine power. Hence, improving HVAC system performance leads to more energy saving of the vehicle which is a critical factor for nowadays automotive. Besides, one crucial...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016