Fibrin glue eliminates the need for packing after complex liver injuries.
نویسندگان
چکیده
Hemostasis after traumatic liver injury can be extremely difficult to obtain, particularly in coagulopathic patients who have suffered extensive liver damage. We determined the ability of a fibrin glue preparation (FG) to terminate ongoing bleeding using a new, clinically relevant porcine model of complex hepatic injury. Anesthetized swine (n = 6, 18 to 19 kg) received an external blast to the right upper abdomen and were immediately anticoagulated with intravenous heparin (200 u/kg). Uncontrolled hemorrhage from blast continued from time of injury (t = 0 minutes) to t = 15 minutes. Lactated Ringer's solution was infused to keep mean arterial pressure (MAP) > 80 mm Hg until the end of experiment (t = 90 minutes). Animals underwent routine surgical techniques to control bleeding, and FG was employed in the event these measures failed. Estimated blood loss and fluid resuscitation volume were measured. Serial MAP, arterial base excess, and temperature were recorded. Animals were severely injured with significant blood loss prior to laparotomy (26 +/- 6 cc/kg) and during routine surgical efforts to arrest hemorrhage (11 +/- 2 cc/kg). Bleeding could not be controlled with standard techniques in any animal. FG rapidly controlled hemorrhage and eliminated the need for packing. Re-bleeding was noted in only one animal (portal vein injury). FG can control severe hepatic hemorrhage when surgical techniques fail. Further work in the clinical arena is warranted to determine the potential benefits of FG in arresting hemorrhage in hemodynamically unstable coagulopathic patients with complex hepatic injuries.
منابع مشابه
A Novel Method for Iatrogenic Vesicovaginal Fistula Treatment: Autologous Platelet Rich Plasma Injection and Platelet Rich Fibrin Glue Interposition
Introduction: Vesicovaginal fistula remains a challenge in surgical therapy. In this study autologous platelet rich plasma and platelet rich fibrin glue were used as a minimally invasive approach for vesicovaginal fistula closure. Materials and Methods: Data including age, parity, ICIQ-UI (International Consultation on Incontinence Questionnaire-urinary incontinence), ICIQ-QOL (Internation...
متن کامل[The use of fibrin glue for the repair of experimental nasal CSF leak in rats].
Surgical repair of cerebrospinal fluid (CSF) leak requires the production of a seal competent to resist CSF pressure during the period of healing. Direct suturing, packing with muscle and fat grafts, and coverage with mucosal or muscle flaps have been effective in repairing most CSF leaks. Fibrin glue will improve the results of a CSF leak repair by providing better adhesion of the graft and im...
متن کاملFibrin glue in the management of complex anal fistula.
CONTEXT Management of complex anal fistulas is associated with the risk of sphincter injury and fecal incontinence. In recent years, fibrin glue has emerged as an alternative sphincter-preserving treatment for anal fistulas. To date, however, there is no consensus about the efficacy of the method. OBJECTIVE To specifically evaluate the fibrin glue injection in the management of complex crypto...
متن کاملPREPARATION OF FIBRIN GLUE AS A BIOLOGICAL SEALANT TO CONTROL BLEEDING IN HEART MUSCLE AND BLOOD VESSELS
Fibrin glue is used for control of bleeding in various surgical procedures. In this work the ability of fibrin glue to seal punctures in the vascular system is demonstrated. Blood samples were taken from rabbits, fibrinogen was separated and fibrin glue was eventually prepared. The rabbits were anesthetized and a midline incision was carried out. The heart and abdominal aorta were exposed. ...
متن کاملFibrin Glue in Postlaryngectomy Fistula-A Case Report
Introduction: One of the most common complications following total laryngectomy is pharyngocutaneous fistula (PCF). Various methods have been proposed to treat this disorder in recent studies, including a range of simple and conservative treatments to more aggressive therapies, such as various surgical procedures. One of the most innovative and least developed methods is the use of plasma...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Yale Journal of Biology and Medicine
دوره 74 شماره
صفحات -
تاریخ انتشار 2001