Proton irradiation of simulated ocular tumors.

نویسندگان

  • I J Constable
  • A M Koehler
  • R A Schmidt
چکیده

Silicone sponges were sutured to the sclera of owl monkeys to create an indentation which would simulate a tumor of the posterior segment of the eye. A tantalum clip inserted in the silicone sponge served as a marker for radiographic localization of the simulated tumors. The acute lesions obtained on the retina and choroid after moderately high doses of proton irradiation suggest that this method of aiming the proton beam will be adquate for human clinical trials.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Proton irradiation for peripapillary and parapapillary melanomas.

OBJECTIVE To examine ocular outcomes and survival after proton irradiation in patients with peripapillary and parapapillary melanomas ineligible for the Collaborative Ocular Melanoma Study. METHODS A total of 573 patients who received proton irradiation from January 4, 1985, through December 24, 1997, for tumors located within 1 disc diameter of the optic nerve, and therefore ineligible for t...

متن کامل

طراحی و بهینه‌سازی طیف نوترونی برای درمان تومورهای عمیق مغزی به روش BNCT با کاهش آسیب رسیده به پوست

Boron neutron capture therapy (BNCT) is an effective method for treatment of deep seated brain tumors. This method consists of two stages: injection of boron compound in the patient body, and then irradiation of the region tumors with the neutron beam. It allows for delivery of high linear energy transfer (LET) radiation (particles 4He and 7Li nuclei) to tumors at the cellular level whilst avoi...

متن کامل

Dosimetric investigation of beta-emitting ophthalmic plaques for treatment of ocular tumors

Understanding the dose distribution of beta-emitting eye plaques respect to the location of tumor is of importance. In this study, the geometry of CCB, COB and CIB plaques (BEBIG manufacturer) for specific eye tumors were simulated and the effects of different coated radionuclides and plaque materials were investigated, by Geant4 simulation toolkit. For validation, a dosimetric investigation wa...

متن کامل

Dose Assessment of Eye and Its Components in Proton Therapy by Monte Carlo Method

Introduction Proton therapy is used to treat malignant tumors such as melanoma inside the eye. Proton particles are adjusted according to various parameters such as tumor size and position and patient’s distance from the proton source. The purpose of this study was to assess absorbed doses in eyes and various tumors found in the area of sclera and choroid and the adjacent tissues in radiotherap...

متن کامل

Effects of Defining Realistic Compositions of the Ocular Melanoma on Proton Therapy

Background: Recent studies in eye plaque brachytherapy have shown a considerable difference between the dosimetric results using water phantom and a model of human eye containing realistic materials. In spite of this fact, there is a lack of simulation studies based on such a model in proton therapy literatures. In the presented work, the effect of utilizing an eye model with ocular media on pr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Investigative ophthalmology

دوره 14 7  شماره 

صفحات  -

تاریخ انتشار 1975