Effects of age on peripheral ocular aberrations.

نویسندگان

  • Ankit Mathur
  • David A Atchison
  • W Neil Charman
چکیده

On-axis monochromatic higher-order aberrations increase with age. Few studies have been made of peripheral refraction along the horizontal meridian of older eyes, and none of their off-axis higher-order aberrations. We measured wave aberrations over the central 42 degrees x32 degrees visual field for a 5mm pupil in 10 young and 7 older emmetropes. Patterns of peripheral refraction were similar in the two groups. Coma increased linearly with field angle at a significantly higher rate in older than in young emmetropes (-0.018+/-0.007 versus -0.006+/-0.002 microm/deg). Spherical aberrationC40was almost constant over the measured field in both age groups and mean values across the field were significantly higher in older than in young emmetropes (+0.08+/-0.05 versus +0.02+/-0.04 microm). Total root-mean-square and higher-order aberrations increased more rapidly with field angle in the older emmetropes. However, the limits to monochromatic peripheral retinal image quality are largely determined by the second-order aberrations, which do not change markedly with age, and under normal conditions the relative importance of the increased higher-order aberrations in older eyes is lessened by the reduction in pupil diameter with age. Therefore it is unlikely that peripheral visual performance deficits observed in normal older individuals are primarily attributable to the increased impact of higher-order aberration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of optimized photorefractive keratectomy (PRK) operation on the asphericity and high-order aberration changes

Background: Optimized is a common and important method in which aberrations are created by the device and the surgeon, but high-grade aberrations are out of the surgeon's control and are induced by the device in the patient. The aim of this study was the evaluation of out-of-control high-order aberration changes before and after PRK surgery and these impact on vision outcome. Materials and meth...

متن کامل

In vitro radioprotective effects of histamine H2 receptor antagonist against gamma-rays induced chromosomal aberrations in human lymphocytes.

Background: Radioprotective capability of histamine H2 receptor antagonists have been shown in several in vivo studies mainly using animal models. However, to verify the effectiveness of these agents in clinical applications, studies should be performed on human cells. In the present study radioprotective properties of these agents was examined in vitro on human lymphocytes using metaphase anal...

متن کامل

Invesitgating the Radioprotective Effect of Brewed Rosa damascene in Comparison with Vitamin E on X-ray Induced Chromosomal Aberrations in Human Peripheral Blood Lymphocytes Using Micronucleus Assay in Binucleated Cells

Aims: More people, for occupational and therapeutic purposes, is exposed to its harmful effects including chromosomal abnormalities every day. Radioprotective agents are able to reduce these kinds of damages through mechanisms such as free radical scavenging, donating hydrogen to damaged molecules and increasing activity of antioxidant enzymes. Medicinal plants which have been traditionally use...

متن کامل

CYTOGENETIC EFFECTS OF MAGNETIC AND RADIOFREQUENCY FIEL DS OF NMRI SYSTEMS ON THE FREQUENCY OF CHROMOSOMAL ABERRATIONS INHUMAN LYMPHOCYTES IN THE PRESENCE OR ABSENCE OF CYTOSINE ARABINOSIDE

Application of nuclear magnetic resonance imaging (NMRI) as a non-invasive and accurate imaging procedure has been widely used in recent years. Meanwhile, the biological effects of magnetic fields of several tesla (T) and high energy radiofrequency (RF) is not fully known yet. Because of controversy over this issue, the present research has been carried out in order to verify the effects of...

متن کامل

Effects of 35 Hz, 2 mT Magnetic Field on Peripheral Blood Lymphocytes of Human In Vitro and Rat In Vivo

In this research we have studied the effects of extremely low frequency magnetic field on the peripheral blood lymphocytes chromosomes of human in vitro and rat in vivo. By this means, we used 60 blood samples of 10 men as well as 40 rats. Of 60 human blood samples ,40 samples (in two group of 20) were selected as test groups and placed into the 2 mT and 35 Hz magnetic field. The blood samples,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics express

دوره 18 6  شماره 

صفحات  -

تاریخ انتشار 2010