Comparison of the analgesic potency of xenon and nitrous oxide in humans evaluated by experimental pain.
نویسندگان
چکیده
We have compared the analgesic potency of MAC-equivalent concentrations of xenon (10, 20, 30 and 40%) and nitrous oxide (15, 30, 45 and 60%) in humans using a multimodal experimental pain testing and assessment technique. We tested 12 healthy volunteers in a randomized, single-blind, crossover study. The following experimental pain tests were used: nociceptive reflex to repeated stimuli; pain tolerance to maximal effort tourniquet ischaemia; electrical stimulation; mechanical pressure; and cold. Reaction time was also measured. Xenon and nitrous oxide produced analgesia to ischaemic, electrical and mechanical stimulation, but not to cold pain. There was no difference in MAC-equivalent concentrations of xenon and nitrous oxide. Both increased reaction time in a similar manner. Xenon and nitrous oxide evoked nausea and vomiting in a large number of volunteers.
منابع مشابه
Xenon suppresses nociceptive reflex in newborn rat spinal cord in vitro; comparison with nitrous oxide.
Although analgesic action of xenon has been reported, little is known about the effect of xenon at the spinal cord, which plays a crucial role in nociceptive transmission. We studied the effect of xenon on nociceptive reflex (the slow ventral root potential) and the monosynaptic reflex in neonatal rat spinal cord in vitro in comparison with nitrous oxide. Xenon (30%) and nitrous oxide (30%) wer...
متن کاملSafety and efficacy of xenon in routine use as an inhalational anaesthetic.
40 patients (24 male, 16 female, aged 21-59 years) of American Society of Anesthesiologists class I or II who were undergoing routine surgery took part in a randomised, double-blind comparison of the anaesthetic efficacy and potency of xenon and nitrous oxide and their effects on the circulatory and respiratory systems. During anaesthesia, for each rise in blood pressure of more than 20% of the...
متن کاملAnalgesic and physiological effects in conscious sedation with different nitrous oxide concentrations
OBJECTIVES to study the physiological changes, as well as the psychosedative and analgesic effects of nitrous oxide, in experimental conditions. STUDY DESIGN 101 dental students volunteers participated in a single nitrous oxide sedation session without dental treatment. Signs and symptoms were registered during and after the procedure. Pulse rate and hemoglobin oxygen saturation were monitore...
متن کاملبررســی مقایســه ای اثــر بــی دردی استنشــاق گاز انتونوکــس بــه تنهایــی و در ترکیــب بــا دگزامتــازون در زایمــان بــی درد
Aim and background: Labor pain is often severe. Unrelieved labor pain can have adverse effects on the physiologic status of mother. Pain during labor is accompanied by fear, which is related to slower progress of labor. Accurate measurement and appropriate management of pain is of great concern for medical and nursing personnel. There are choices to be made during pregnancy about options avail...
متن کاملAnalgesic interaction between nitrous oxide and delta-9-tetrahydrocannabinol in the rat.
The analgesic activities of a 75:25% nitrous oxide-oxygen mixture administered for 15 min, of delta-9-tetrahydrocannabinol (THC) 10 mg kg-1 i.p., and of a combination of both, were evaluated in the rat by tail-flick and hot-plate tests. The nitrous oxide-oxygen mixture produced a significant increase in the pain threshold. The analgesic activity of THC was similar in extent but of longer durati...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 81 5 شماره
صفحات -
تاریخ انتشار 1998