In vitro assessment of ultrasonic lithotriptors.
نویسندگان
چکیده
PURPOSE Ultrasonic lithotriptors are commonly used to fragment and remove stones during percutaneous nephrolithotomy. To date a comparative assessment of current units has not been accomplished without potential operator bias. An objective testing environment is required for optimal appraisal of the efficiency of ultrasonic lithotriptors. MATERIALS AND METHODS An in vitro test system was devised to evaluate the ability of ultrasonic lithotriptors to core through artificial stones. The system consisted of an irrigation sheath (Cook Urological, Spencer, Indiana) through which ultrasonic probes were placed. Ultrasonic hand pieces and probes were secured in an upright position. An Ultracal-30 (U.S. Gypsum, Chicago, Illinois) stone cylinder (mean length 12.8 +/- 0.6 mm, mean diameter 7.6 +/- 0.07 mm) was centered on the probe tip. A weight (62.7 gm) was placed atop the stone to provide a constant force. We evaluated the Olympus LUS-1 and LUS-2 (Olympus, Melville, New York), Circon-ACMI USL-2000 (Circon-ACMI, Southborough, Massachusetts), Karl Storz Calcuson (Karl Storz, Culver City, California) and Richard Wolf model 2271.004 (Richard Wolf, Vernon Hills, Illinois). All probes had outer diameters of 3.4 mm except for the Circon-ACMI unit (3.8 mm). Using 100% power settings times for complete stone penetration were assessed for all units. Differences in mean stone penetration times were compared using ANOVA. RESULTS The Olympus LUS-2 had the fastest mean stone penetration time (28.8 +/- 2.7 seconds). This value was used to normalize the data into efficiency ratios, where other unit times were expressed as multiples of the LUS-2 time: Olympus LUS-2 (1.0 +/- 0.1) equals Circon-ACMI USL-2000 (1.1 +/- 0.3) greater than Karl Storz Calcuson (1.4 +/- 0.3) greater than Olympus LUS-1 (2.1 +/- 0.5) greater than Richard Wolf (3.6 +/- 0.8). Efficiencies of the LUS-2 and USL-2000 units were essentially equivalent, with all others significantly less efficient (p <0.05). CONCLUSIONS This new in vitro testing model provides an objective, reproducible method for evaluating the efficiency of intracorporeal lithotriptors. Of the units tested the Olympus LUS-2 and Circon-ACMI USL-2000 were the most efficient.
منابع مشابه
Comparison of Ultrasonic and Pneumatic Intracorporeal Lithotripsy Techniques during Percutaneous Nephrolithotomy
OBJECTIVES To compare the effectiveness and safety of ultrasonic and pneumatic lithotripters in the treatment of renal stone disease. MATERIALS AND METHODS A total of 227 consecutive percutaneous nephrolithotomy procedures for renal calculi were performed. In 107 patients ultrasonic lithotriptors were used (group I) and in 83 patients pneumatic lithotriptors were used (group II). In the remai...
متن کاملAccuracy Assessment of Ultrasonic C-scan and X-ray Radiography Methods for Impact Damage Detection in Glass Fiber Reinforced Polyester Composites
The present study introduces two quantitative parameters to compare the accuracy of ultrasonic C-scan testing and X-ray radiography methods in the damaged area detection under low-velocity impact in polymer-based composites. For this purpose, the hand lay-up technique of composite processing was employed to prepare the composite specimen. A composite specimen consisting of the glass fiber reinf...
متن کاملI-42: Advanced Ultrasonic Techniques in The Assessment of Early Human Development
Background: To evaluate the role of 3D, 4D and color Doppler ultrasound (US) in the assessment of early human development. Materials and Methods: 380 women with uncomplicated early pregnancy between 5 and 14 weeks were evaluated by 3D, 4D and color Doppler US. Results: Regression analysis revealed exponential rise of the gestational sac volume with gestational age throughout the first trimester...
متن کاملInnovations in shock wave lithotripsy technology: updates in experimental studies.
PURPOSE We developed innovations in shock wave lithotripsy (SWL) technology. MATERIALS AND METHODS Two technical upgrades were implemented in an original unmodified HM-3 lithotriptor (Dornier Medical Systems, Inc., Kennesaw, Georgia). First, a single unit ellipsoidal reflector insert was used to modify the profile of lithotriptor shock wave (LSW) to decrease the propensity of tissue injury in...
متن کاملUltrasonic Assisted Synthesis, Characterization and Bioactivity Assessment of Novel Piperonal Based Schiff Base and Its Metal Complexes
A novel Schiff base was synthesized by the reaction of piperonal and anthranilic acid, which was further utilized in the synthesis of five novel complexes by reaction with different metal salts ultrasonically. Time for the reaction was greatly reduced through ultrasound irradiations and the yield of reactions was also high as compared to the conventional methods using reflux conditions. The...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of urology
دوره 170 4 Pt 1 شماره
صفحات -
تاریخ انتشار 2003