Investigating the Group-Level Impact of Advanced Dual-Echo fMRI Combinations
نویسندگان
چکیده
Multi-echo fMRI data acquisition has been widely investigated and suggested to optimize sensitivity for detecting the BOLD signal. Several methods have also been proposed for the combination of data with different echo times. The aim of the present study was to investigate whether these advanced echo combination methods provide advantages over the simple averaging of echoes when state-of-the-art group-level random-effect analyses are performed. Both resting-state and task-based dual-echo fMRI data were collected from 27 healthy adult individuals (14 male, mean age = 25.75 years) using standard echo-planar acquisition methods at 3T. Both resting-state and task-based data were subjected to a standard image pre-processing pipeline. Subsequently the two echoes were combined as a weighted average, using four different strategies for calculating the weights: (1) simple arithmetic averaging, (2) BOLD sensitivity weighting, (3) temporal-signal-to-noise ratio weighting and (4) temporal BOLD sensitivity weighting. Our results clearly show that the simple averaging of data with the different echoes is sufficient. Advanced echo combination methods may provide advantages on a single-subject level but when considering random-effects group level statistics they provide no benefit regarding sensitivity (i.e., group-level t-values) compared to the simple echo-averaging approach. One possible reason for the lack of clear advantages may be that apart from increasing the average BOLD sensitivity at the single-subject level, the advanced weighted averaging methods also inflate the inter-subject variance. As the echo combination methods provide very similar results, the recommendation is to choose between them depending on the availability of time for collecting additional resting-state data or whether subject-level or group-level analyses are planned.
منابع مشابه
The quest for the best: The impact of different EPI sequences on the sensitivity of random effect fMRI group analyses
We compared the sensitivity of standard single-shot 2D echo planar imaging (EPI) to three advanced EPI sequences, i.e., 2D multi-echo EPI, 3D high resolution EPI and 3D dual-echo fast EPI in fixed effect and random effects group level fMRI analyses at 3T. The study focused on how well the variance reduction in fixed effect analyses achieved by advanced EPI sequences translates into increased se...
متن کاملfMRI of the brainstem using dual-echo EPI
The brainstem is the part of the human brain that plays a pivotal role in the maintenance of many critical body functions. Due to the elevated level of cardiogenic noise, few fMRI studies have investigated the brainstem so far. Cardiac-gated echo-planar imaging with acquisition of two echoes per excitation (dual-echo EPI) is one method that significantly reduces cardiogenic noise and, thus, all...
متن کاملTechnical Note fMRI of the brainstem using dual-echo EPI
The brainstem is the part of the human brain that plays a pivotal role in the maintenance of many critical body functions. Due to the elevated level of cardiogenic noise, few fMRI studies have investigated the brainstem so far. Cardiac-gated echo-planar imaging with acquisition of two echoes per excitation (dual-echo EPI) is one method that significantly reduces cardiogenic noise and, thus, all...
متن کاملEffect of Phase-Encoding Reduction on Geometric Distortion and BOLD Signal Changes in fMRI
Introduction Echo-planar imaging (EPI) is a group of fast data acquisition methods commonly used in fMRI studies. It acquires multiple image lines in k-space after a single excitation, which leads to a very short scan time. A well-known problem with EPI is that it is more sensitive to distortions due to the used encoding scheme. Source of distortion is inhomogeneity in the static B0 field that ...
متن کاملEvaluation of Sensory Pathways in Spinal Cord by Comparison of fMRI Methodologies
Introduction: Today, clinicians and neuroscientists need to have a comprehensive survey of neurological pathologies and injuries. For the First-time, SEEP contrast and Spin-Echo pulse sequences was used for functional imaging of the Lumbar spinal cord. This method used by several research groups for Spinal cord mapping, but other researchers tried to improve BOLD fMRI to Spina...
متن کامل