Aqueous humor dynamics in mice.
نویسندگان
چکیده
PURPOSE To assess aqueous humor dynamics in mouse eyes. METHODS Aqueous humor dynamics of NIH Swiss White mouse were assessed with an injection and aspiration system, using fine glass microneedles. Intraocular pressure (IOP) was measured by a microneedle connected to a pressure transducer. Episcleral venous pressure (EVP) was measured by gradually lowering intracameral pressure until blood reflux into Schlemm's canal was observed. Outflow facility (C) was determined based on constant pressure perfusion measurements obtained at two different IOPs. Aqueous volume (V(a)) was determined by direct measurement of aspirated aqueous humor. Aqueous humor production (F(a)) was measured by the dilution method with rhodamine-dextran. Conventional and uveoscleral outflow (F(c) and F(u), respectively), as well as the turnover rate of aqueous humor, were also calculated. RESULTS IOP and EVP were 15.7 +/- 2.0 and 9.5 +/- 1.2 mm Hg, respectively (n = 20). F(a) was 0.18 +/- 0.05 microL/min (mean +/- SD; n = 8). C was 0.0051 +/- 0.0006 microL/min per mm Hg (n = 8). Estimated F(c) and F(u) were 0.032 and 0.148 microL/min, respectively. F(c) was 18% of F(a). F(u) was 82% of F(a). V(a) was 5.9 +/- 0.5 microL (n = 8). The calculated turnover rate of aqueous humor was 2.5%. CONCLUSIONS The mouse eye has similar aqueous production and aqueous humor turnover rate as the human eye. The presence of both conventional and uveoscleral outflow suggests that the mouse is a useful model system for further investigations of the biology of aqueous dynamics.
منابع مشابه
Enhanced inflow and outflow rates despite lower IOP in bestrophin-2-deficient mice.
PURPOSE Bestrophin-2 (Best2), a putative Cl(-) channel is expressed in the nonpigmented epithelium (NPE). Disruption of Best2 in mice results in a diminished intraocular pressure (IOP). Aqueous humor dynamics were compared in Best2(+/+) and Best2(-/-) mice, to better understand the contribution of Best2 to IOP. METHODS Measurements of IOP, episcleral venous pressure (EVP), conventional outflo...
متن کاملNoninvasive assessment of aqueous humor turnover in the mouse eye.
PURPOSE To develop a noninvasive test for monitoring changes in aqueous humor turnover in the mouse eye. METHODS After topical instillation of fluorescein, the rate of decay of fluorescence from aqueous humor and cornea was monitored in Black Swiss, C57 Bl6, and DBA 2J mice with a microscope equipped with epifluorescence and a charge-coupled device (CCD) camera. RESULTS The rate of decay of...
متن کاملCorrelations between parameters of aqueous humor dynamics and the influence of central corneal thickness.
PURPOSE The individual parameters of aqueous humor dynamics may influence each other to maintain intraocular pressure (IOP) homeostasis. Central corneal thickness (CCT) is known to be associated with onset and progression of glaucoma and can potentially influence the individual parameters of aqueous humor dynamics that maintain IOP. This study investigates the correlation between parameters of ...
متن کاملThe aqueous humor outflow pathway of zebrafish.
PURPOSE The structures of the ocular anterior segment responsible for aqueous humor secretion and absorption have been well characterized in mammals. However, the underlying molecular and cellular mechanisms that regulate aqueous humor flow have remained elusive. Experimental analysis in Danio rerio, the zebrafish, is providing mechanistic insights into many cellular processes relevant to norma...
متن کاملThe Effect of Vanadate on Aqueous Humor Dynomics in Cynomolgus Monkeys
3. Eakins K: The effect of intravitreous injections of norepinephrine, epinephrine and isoproterenol on the intraocular pressure and aqueous humor dynamics of rabbit eyes. J Pharmacol Exp Ther 140:79, 1963. 4. Gaasterland D, Kupfer C, Ross K, and Gabelnick HL: Studies of aqueous humor dynamics in man. III. Measurements in young normal subjects using norepinephrine and isoproterenol. Invest Opht...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 44 12 شماره
صفحات -
تاریخ انتشار 2003