Internal thoracic artery to left anterior descending anastomosis performed on the beating heart by endoscopic robot assistance using a new distal connector.

نویسندگان

  • Inderjit S Gill
  • Hironori Izutani
چکیده

BACKGROUND Automated distal connecting devices have been recently introduced to facilitate coronary anastomosis. This could have a large impact on the capacity of robotic systems to perform completely endoscopic off-pump bypass, where the quality of anastomosis and the prolonged operative time for the performance of the anastomosis have until now been cause for concern. Our group tried to determine the feasibility and efficacy of the JoMed distal graft connector using the ZEUS robotic system. METHODS Six swine, with a mean weight of 25.8 (standard deviation [SD] 2.2) kg, underwent endoscopic off-pump internal thoracic artery-left anterior descending (ITA-LAD) anastomosis with a special stabilizing system using ZEUS robotic assistance. The anastomosis was performed with the JoMed distal connector. RESULTS The connector was employed successfully in 4 of 6 cases using a special delivery instrument. Two animals fibrillated within 2 minutes after the application of proximal occluding snares and were excluded from the analysis. The total device deployment time was 2 minutes 4 seconds (SD 50 s) in 4 of 6 survivors, which remained hemodynamically stable and in sinus rhythm until euthanasia. Coronary angiography and transonic flow measurements were used to verify patency. CONCLUSION The JoMed distal graft connector may facilitate the use of robot-assisted endoscopic bypass on a beating heart. Long-term patency issues will need to be assessed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Facilitated endoscopic beating heart coronary artery bypass grafting using a magnetic coupling device.

BACKGROUND Suturing of a coronary anastomosis in totally endoscopic coronary artery bypass grafting on the beating heart is technically demanding. The potential benefits of the endoscopic Magnetic Vascular Positioner device (Ventrica, Inc, Fremont, Calif) to facilitate construction of a coronary anastomosis in a closed chest environment were evaluated. METHODS Totally endoscopic coronary arte...

متن کامل

Early and midterm results of totally endoscopic coronary artery bypass grafting on the beating heart.

OBJECTIVE Despite the early introduction of totally endoscopic coronary artery bypass on the beating heart, only a limited number of cases have been performed. The limiting factor has been the concern about safety and graft patency of the anastomosis. This study describes our experience with totally endoscopic coronary artery bypass on the beating heart with robotic assistance and its early and...

متن کامل

Robotically enhanced coronary artery bypass surgery

Robotically enhanced telemanipulation surgery is a rapidly developing technique which enables totally endoscopic cardiac surgery with utmost precision and perfection on both beating heart and arrested heart. Between December 2002 and September 2006, 268 patients underwent robotically enhanced coronary artery bypass surgery using the da Vinci telemanipulation system. Fourteen patients underwent ...

متن کامل

Clinical and six-month angiographic evaluation of coronary arterial graft interrupted anastomoses by use of a self-closing clip device: a multicenter prospective clinical trial.

OBJECTIVES To evaluate the safety and effectiveness of a self-closing surgical clip with an interrupted technique in left internal thoracic artery to left anterior descending artery bypass grafting. METHODS Eighty-two patients were enrolled and treated (February 2000 through August 2001) in a prospective, nonrandomized, multicenter trial. Left internal thoracic artery to left anterior descend...

متن کامل

History and current status of robotic totally endoscopic coronary artery bypass.

Robotic totally endoscopic coronary artery bypass (TECAB) is a minimally invasive endoscopic surgical approach using the daVinci robotic telemanipulation system to perform coronary artery bypass grafting on the arrested or beating heart. It is a procedure that can be a useful alternative to the classic open procedure performed through sternotomy. After extensive modeling in cadavers, the first ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Canadian journal of surgery. Journal canadien de chirurgie

دوره 49 1  شماره 

صفحات  -

تاریخ انتشار 2006