In vitro comparison of the amount of salbutamol available for inhalation from different formulations used with different spacer devices.
نویسندگان
چکیده
Metered-dose inhalers (MDIs) are currently being reformulated to contain hydrofluoroalkanes (HFAs), which do not damage the Earth's ozone layer. As different formulations of inhaled drugs may behave differently when used with spacer devices, we wished to determine the amount of salbutamol available for inhalation from a conventional metered-dose inhaler (Ventolin) and a new HFA-containing formulation (Airomir), when used with two different spacers. A glass multistage liquid impinger was used to determine the amount of salbutamol delivered from the inhalers used with the Aerochamber and the Nebuhaler spacer devices. High speed video-recordings of inhaler actuation into air were made, and the speed of the aerosol and the aerosol cloud volume were measured. More salbutamol in small particles (<5 microm) was delivered from the Airomir MDI than the Ventolin MDI, when used with the Aerochamber (40.4 (95% confidence interval (95% CI) 31.2-49.6) versus 19.5 (19.0-20.0) microg) and the Nebuhaler (42.1 (36.3-47.9) versus 24.6 (23.3-25.8) microg). The aerosol cloud from the Airomir MDI was slower than the Ventolin aerosol, and 60 ms after actuation had travelled 186 mm, whereas the Ventolin aerosol had travelled 320 mm. At the same time, the Airomir aerosol occupied a smaller volume than the Ventolin MDI (251 (213-288) versus 695 (608-782) cm3). The hydrofluoroalkane formulation delivers more salbutamol than the conventional formulation when used either with the Aerochamber or Nebuhaler spacer. This may be because less drug is deposited in the spacer from the hydrofluoroalkane formulation, which is emitted from the metered-dose inhaler at a slower speed and occupies a smaller volume than the conventional formulation. The observed difference in drug delivery may be important for patients changing formulations, and in severe asthma, where high doses of salbutamol may be administered through a spacer.
منابع مشابه
Inhalational drug delivery from seven different spacer devices.
BACKGROUND A study was performed to determine in vitro the difference in drug output of seven currently available spacer devices when used with different inhaled medications. METHODS A glass multistage liquid impinger (MSLI) was used to determine the amount of disodium cromoglycate (DSCG, 5 mg), salbutamol (100 micrograms), or budesonide (200 micrograms) obtained in various particle size rang...
متن کاملEffect of multiple actuations, delayed inhalation and antistatic treatment on the lung bioavailability of salbutamol via a spacer device.
BACKGROUND The aim of this study was to extend previous in vitro observations regarding the effects of multiple actuations of aerosols into spacer devices, delayed inhalation, and antistatic treatment of spacer devices on the amount of drug delivered for inhalation. An in vivo study of lung bioavailability of salbutamol from a large volume (Volumatic) spacer was conducted. METHODS Ten healthy...
متن کاملDesign and Comparative Evaluation of In-vitro Drug Release, Pharmacokinetics and Gamma Scintigraphic Analysis of Controlled Release Tablets Using Novel pH Sensitive Starch and Modified Starchacrylate Graft Copolymer Matrices
The present investigation deals with the development of controlled release tablets of salbutamol sulphate using graft copolymers (St-g-PMMA and Ast-g-PMMA) of starch and acetylated starch. Drug excipient compatibility was spectroscopically analyzed via FT-IR, which confirmed no interaction between drug and other excipients. Formulations were evaluated for physical characteristics like hardness,...
متن کاملThe protective effect of salbutamol inhaled using different devices on methacholine bronchoconstriction.
STUDY OBJECTIVE To determine the protective effect of salbutamol, 100 microg, inhaled by different devices (pressurized metered-dose inhaler [pMDI; Ventolin; GlaxoWellcome; Greenford, UK], pMDI + spacer [Volumatic; GlaxoWellcome], or breath-activated pMDI [Autohaler; 3M Pharmaceuticals; St. Paul, MN]) on bronchoconstriction induced by methacholine. DESIGN Randomized, double-blind, cross-over,...
متن کاملDesign and Comparative Evaluation of In-vitro Drug Release, Pharmacokinetics and Gamma Scintigraphic Analysis of Controlled Release Tablets Using Novel pH Sensitive Starch and Modified Starchacrylate Graft Copolymer Matrices
The present investigation deals with the development of controlled release tablets of salbutamol sulphate using graft copolymers (St-g-PMMA and Ast-g-PMMA) of starch and acetylated starch. Drug excipient compatibility was spectroscopically analyzed via FT-IR, which confirmed no interaction between drug and other excipients. Formulations were evaluated for physical characteristics like hardness,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The European respiratory journal
دوره 10 6 شماره
صفحات -
تاریخ انتشار 1997