The optimization of the separation resolution for a group of N-phenylpyrazole derivatives in micellar electrokinetic chromatography (MEKC) as a function of the separation buffer composition (surfactant and organic modifier concentration) has been performed. In order to achieve our purpose, the first step has been the prediction of the migration times of the electroosmotic flow (t(0)) and micelles (t(m)), and the retention factors of solutes (k), as a function of surfactant (sodium dodecyl sulfate) and alcohol (n-propanol or n-butanol) concentrations, by means of empirical equations. Also, some physicochemical models have been applied to relate the retention factors to the surfactant and the organic modifier concentrations in order to optimize the separation resolution and to increase our knowledge of the separation process. Finally, a comparison of the resolution optimization through the use of the physicochemical and empirical models selected has been made in order to obtain the optimum separation buffer composition for the separation of a group of 17 N-phenylpyrazole derivatives as test solutes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modeling The Capacity Factor of Analytes in Micellar Electrokinetic Chromatography Using Computational Descriptors

       A multiple linear regression model is proposed to calculate capacity factor of  analytes using structural features computed using HyperChem software. The  chemical descriptors of analytes were computed using HyperChem software and  regressed against the experimental capacity factors of analytes collected from the  literature. The absolute average percentage deviation (AARD) and individua...

متن کامل

Micellar liquid chromatography (Review). Part 1. Fundamentals, retention models and optimization of separation

First part of review Micellar liquid chromatography is devoted to fundamentals and problems of retention modeling and optimization of separation. The 117 literature references have been critically analyzed. The known conceptual, mechanistic and empirical retention models are reviewed, classified and discussed. The methodologies of optimization of separation in high-performance liquid chromatogr...

متن کامل

Polymeric sulfated surfactants with varied hydrocarbon tail: I. Synthesis, characterization, and application in micellar electrokinetic chromatography.

The influence of surfactant hydrocarbon tail on the solute/pseudostationary phase interactions was examined. Four anionic sulfated surfactants with 8-, 9-, 10-, and 11-carbon chains having a polymerizable double bond at the end of the hydrocarbon chain were synthesized and characterized before and after polymerization. The critical micelle concentration (CMC), polarity, and aggregation number o...

متن کامل

Migration behaviour of monovalent weak acids in micellar electrokinetic chromatography Mobility model versus retention model

Migration of charged compounds in micellar electrokinetic chromatography (MEKC) is based on micellar solubilization as well as electrophoretic migration. Consequently, the migration behaviour of these compounds can be described with a retention model or a mobility model. Both models are discussed and evaluated for the migration behaviour of monovalent weak acids in a sodium dodecyl sulphate mic...

متن کامل

A Study on Retention of a Series of Aromatic Compounds in Mixed Micellar Liquid Chromatography Using Linear Solvation Energy Relationship (LSER)

The effect of SDS (0.03-0.07 M) and Brij-35(0-0.003 M) concentrations and temperature on retention parameters of 30 solutes in micellar reversed- phase liquid chromatography systems were studied using solvation parameter model. The system constants were determined by multiple linear regression analysis from experimental values of the retention factors with known descriptors by computer usin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Electrophoresis

دوره 24 3  شماره 

صفحات  -

تاریخ انتشار 2003