Influence of digestion procedures on the determination of rare earth elements in peat and plant samples by USN-ICP-MS
نویسندگان
چکیده
Analytical procedures for the determination of rare earth elements (REE) in 250 mg aliquots of difficult-todigest peat and plant matrices by ICP-MS were developed. Three different pressurised digestion approaches were tested for this purpose, namely (i) closed vessel acid digestion on a hot-plate at 180 uC, (ii) digestion in a microwave high pressure autoclave at a temperature of 240 uC and (iii) high pressure ashing (HPA) at a temperature of 320 uC. Acid mixtures for digestion contained concentrated nitric acid (3–5 ml) alone or additions of hydrofluoric acid (HF) or tetrafluoroboric acid (HBF4) at volumes of 0.05–1.0 ml. The selection of appropriate volumes of HF or HBF4 was identified as a critical step in obtaining accurate results. For several reasons, HBF4 is preferred in comparison with the normally used addition of HF for the destruction of siliceous matter in the samples investigated. The optimum acid mixture consisted of 3 ml of HNO3 and 0.1 ml of HBF4. High sample throughput (40 samples simultaneously in about 2 h) favours the microwave autoclave over the other two digestion systems. An ultrasonic nebuliser (USN) with membrane desolvation used for sample introduction reduced the spectral interferences originating from oxide formation of lighter REE and Ba to a negligible extent. Internal standardisation with Rh and Re proved to be essential for obtaining correct results. In this way, all REE could be reliably quantified by USN-ICP-MS without applying any mathematical correction equations. The accuracy of the optimised procedures was assessed by the determination of REE in digests of the certified reference material GBW 07602 Bush Branches and Leaves and of the candidate reference material CRM 670 Aquatic Plant. The developed analytical procedures were applied to the determination of REE in two different peat matrices. Results for these peat samples obtained by USN-ICP-MS showed good agreement with INAA values. Strong fractionation of REE caused by the addition of HF or HBF4 in excess, known as lanthanide contraction, could be experimentally established, except for europium, which revealed a different behaviour.
منابع مشابه
Determination of Rare Earth Elements in Products of Chadormalu Iron Ore Concentrator Plant (Iran) from Beneficiation Point of View
Different samples have been prepared from different products in Chadormalu iron ore concentrator plant: Low intensity magnetite separators concentrate (magnetite concentrate), reverse flotation tail (final hematite concentrate), flotation concentrate (apatite concentrate), final tail (L.I.M.S. tail + reverse flotation concentrate+ apatite flotation tail). The samples were used for rare eart...
متن کاملBio-accumulation of major, trace, and rare earth elements by two Astragalus species grown on Agh-Dareh and Zarshouran gold deposits, Takab, NW Iran
The Agh-Dareh and Zarshouran mines are two known active gold deposits in Takab, NW Iran. In the present study, the potentials of two species of Astragalus (A. microcephalus from Agh-Dareh and A. effusus from Zarshouran mines), as the dominant plants grown in these areas, were assessed for the bio-accumulation of the major, trace, and rare earth elements (REEs). The plant and soil samples were c...
متن کاملDetermination of heavy metals and rare earth elements in environmental samples by ICP-MS after solid phase preconcentration with chelating resin fibers and anion exchanger filters.
A solid phase collection/concentration method using anion exchanger filters and a small syringe packed with chelating resin fibers is adopted as a preconcentration tool for trace elements and a separation tool for matrices in aqueous samples prior to the measurement by inductively coupled plasma-mass spectrometry (ICP-MS). The effects of fiber volume, sample volume, eluent volume, and sample fl...
متن کاملMeasuring the Density of Calcium and Magnesium Elements in Pistachio Leaf by ICP Modern Method and Comparing it With Titration Methods and Atomic Absorption
Introduction: Calcium critical limit in pistachio plants is about 1.3 percent of plant dried material; magnesium critical limit in pistachio leaves is about 0.6 percent of plant dried material. To measure calcium and magnesium there are several methods in which three methods of titration and atomic absorption that are more common and used to libraries more in addition to ICP modern method are u...
متن کاملMeasuring the Density of Calcium and Magnesium Elements in Pistachio Leaf by ICP Modern Method and Comparing it With Titration Methods and Atomic Absorption
Introduction: Calcium critical limit in pistachio plants is about 1.3 percent of plant dried material; magnesium critical limit in pistachio leaves is about 0.6 percent of plant dried material. To measure calcium and magnesium there are several methods in which three methods of titration and atomic absorption that are more common and used to libraries more in addition to ICP modern method are u...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2002