A Two-Component Model for Measurement Error in Analytical Chemistry

نویسندگان

  • David M. ROCKE
  • Stefan LORENZATO
چکیده

In this article, we propose and test a new model for measurement error in analytical chemistry. Often, the standard deviation of analytical errors is assumed to increase proportionally to the concentration of the analyte, a model that cannot be used for very low concentrations. For near-zero amounts, the standard deviation is often assumed constant, which does not apply to larger quantities. Neither model applies across the full range of concentrations of an analyte. By positing two error components, one additive and one multiplicative, we obtain a model that exhibits sensible behavior at both low and high concentration levels. We use maximum likelihood estimation and apply the technique to toluene by gas-chromatography/mass-spectrometry and cadmium by atomic absorption spectroscopy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection limits and goodness-of-fit measures for the two-component model of chemical analytical error

The utility of analytical chemistry measurements in most applications is dependent on an assessment of measurement error. This paper demonstrates the use of a two-component error model in setting limits of detection and related concepts and introduces two goodness-of-fit statistics for assessing the appropriateness of the model for the data at hand. The model is applicable to analytical methods...

متن کامل

Standard Addition Connected to Selective Zone Discovering for Quantification in the Unknown Mixtures

Univariate calibration method is a simple, cheap and easy to use procedure in analytical chemistry. A univariate analysis will be successful if a selective signal can be found for the analyte(s). In this work, two simple ways were used to find the selective signals, spectral ratio plot (SRP) and loading plot (LP). Both of them were able to discover the selective regions in the recorded data set...

متن کامل

Long-term analytical performance of hemostasis field methods as assessed by evaluation of the results of an external quality assessment program for antithrombin.

BACKGROUND It is important for a laboratory to know the stability of performance of laboratory tests over time. The aim of this study was to adapt from the field of clinical chemistry a method to assess the long-term analytical performance of hemostasis field methods. METHODS The linear regression model was used to compare the laboratory results with the consensus mean value of a survey. This...

متن کامل

Modeling uncertainty in the measurement of low-level analytes in environmental analysis.

The use of analytical chemistry measurements in environmental monitoring is dependent on an assessment of measurement error. Models for variation in measurements are needed to quantify uncertainty in measurements, set limits of detection, and preprocess data for more sophisticated analysis in prediction, classification, and clustering. This article explains how a two-component error model can b...

متن کامل

In vivo glucose measurement by surface-enhanced Raman spectroscopy.

This paper presents the first in vivo application of surface-enhanced Raman scattering (SERS). SERS was used to obtain quantitative in vivo glucose measurements from an animal model. Silver film over nanosphere surfaces were functionalized with a two-component self-assembled monolayer, and subcutaneously implanted in a Sprague-Dawley rat such that the glucose concentration of the interstitial f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000