Hemostatic efficacy of two advanced dressings in an aortic hemorrhage model in Swine.

نویسندگان

  • Bijan S Kheirabadi
  • Eric M Acheson
  • Rudolfo Deguzman
  • Jill L Sondeen
  • Kathy L Ryan
  • Angel Delgado
  • Edward J Dick
  • John B Holcomb
چکیده

BACKGROUND An effective hemostatic agent capable of stopping severe arterial bleeding and sustaining hemostasis over a prolonged time is required. The U.S. Army recently distributed fibrin sealant (under an Investigational New Drug-approved protocol) and chitosan dressings among deployed medics for treating severe external hemorrhage on the battlefield. The purpose of this study was to evaluate the efficacy of these dressings, as compared with the standard gauze army field dressing, to provide initial and sustained hemostasis up to 96 hours in a lethal uncontrolled arterial hemorrhage model. METHODS Anesthetized pigs were splenectomized and chronically instrumented for fluid/drug administration and continuous monitoring of vital signs. An infrarenal aortotomy was created using a 4.4-mm aortic hole punch and free bleeding was allowed for 5 seconds. While bleeding profusely, a dressing was applied and pressed into the wound for 4 minutes (occluding the distal flow) and then released. If hemostasis was not obtained, the dressing was replaced with a new one (maximum, two dressings per experiment) with another 4-minute compression. If hemostasis was achieved, the abdomen was closed; the animal was then recovered and monitored up to 96 hours. Initial hemostasis, duration of hemostasis, survival time, blood loss, and other variables were measured. RESULTS Application of army field dressing (gauze) did not stop the arterial hemorrhage and led to exsanguination of all the pigs (n = 6) within 10 to 15 minutes of the injury. Chitosan dressing produced initial hemostasis in five of seven pigs. However, the dressings failed to maintain hemostasis for more than 1.6 hours (range, 28-102 minutes), resulting in secondary bleeding and death of the animals. Fibrin sealant dressing produced initial hemostasis in all the pigs (n = 6) and maintained hemostasis in five cases, with one failure at 2.2 hours. These pigs resumed normal activities and lived for the 96-hour experiment duration. Computed tomographic images and histologic sections of the aortas from surviving fibrin sealant dressing-treated animals showed formation of pseudoaneurysms and early granulation tissue at the aortotomy site. The posttreatment blood loss, duration of hemostasis, and survival time were significantly different in the fibrin sealant dressing group than the chitosan dressing and army field dressing groups. CONCLUSION Both chitosan dressing and fibrin sealant dressing stopped initial arterial bleeding that could not be controlled by the standard army field dressing. However, although the fibrin sealant dressing secured hemostasis for up to 4 days, the chitosan dressing consistently failed within 2 hours after application. There may be a risk of rebleeding for high-pressure arterial wounds treated with chitosan dressings, particularly in situations where definitive care is delayed substantially.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative testing of new hemostatic agents in a swine model of extremity arterial and venous hemorrhage.

OBJECTIVE To compare advanced hemostatic dressings: HemCon (HC), QuikClot ACS+ (advanced clotting sponge, and two granular agents: Celox (CX) and WoundStat (WS), with a standard field dressing in a swine model of extremity hemorrhage. METHODS We randomized 30 animals to treatment with a standard dressing or a hemostatic agent applied to a 2 x 6-mm injury in the femoral artery and vein after 4...

متن کامل

Comparison of 10 different hemostatic dressings in an aortic injury.

BACKGROUND Uncontrolled hemorrhage is the leading preventable cause of death on the battlefield. Similarly, hemorrhage accounts for 80% of all deaths within the first 48 hours of injury in civilian trauma patients. New methods of hemostasis are required to reduce hemorrhagic mortality. The purpose of this study was to compare nine hemostatic dressings for their efficacy in controlling bleeding ...

متن کامل

Effect of a chitosan-based hemostatic dressing on blood loss and survival in a model of severe venous hemorrhage and hepatic injury in swine.

BACKGROUND Hemorrhage is a leading cause of death from trauma. An advanced hemostatic dressing could augment available hemostatic methods. We studied the effects of a new chitosan dressing on blood loss, survival, and fluid use after severe hepatic injury in swine. METHODS Swine received chitosan dressings or gauze sponges. Standardized, severe liver injuries were induced. After 30 seconds, d...

متن کامل

Determination of efficacy of a novel alginate dressing in a lethal arterial injury model in swine.

INTRODUCTION Alginate is a biocompatible polysaccharide that is commonly used in the pharmaceutical, biomedical, cosmetic, and food industries. Though solid dressings composed of alginate can absorb water and promote wound healing, they are not effective hemostatic materials, particularly against massive hemorrhage. The purpose of this study is to attempt to increase the hemostatic capabilities...

متن کامل

Chitosan based advanced hemostatic dressing is associated with decreased blood loss in a swine uncontrolled hemorrhage model.

BACKGROUND The purpose of this study was to compare standard gauze (SG) and advanced hemostatic dressings in use by military personnel in a no-hold model. METHODS A randomized, controlled trial was conducted using 36 swine. Animals underwent femoral arteriotomy, followed by 60 seconds of uncontrolled hemorrhage. After hemorrhage, packing with 1 of 3 dressings-SG, Combat Gauze (CG), or Celox R...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of trauma

دوره 59 1  شماره 

صفحات  -

تاریخ انتشار 2005