The requirements for beamforming in high intensity focused ultrasound (HIFU) for tissue destruction are substantially different than those for diagnostic imaging. High numerical aperture and CW efficiency are desirable for tissue destruction, while depth of focus and broadband sensitivity are key to good imaging. When the same transducer must be used for ablation and imaging some compromises must be made, resulting in non-ideal beam patterns. Predicting the dosage in tissue that results from actual beam patterns becomes a key element in designing such systems. Quantitative schlieren images in CW mode are used to provide fast, high dynamic range field maps in water. The image data are then corrected for attenuation, resulting in simulated beam profiles and absorbed dose rates for tissue.
منابع مشابه
Numerical Study for Optimizing Parameters of High-Intensity Focused Ultrasound-Induced Thermal Field during Liver Tumor Ablation: HIFU Simulator
Introduction High intensity focused ultrasound (HIFU) is considered a noninvasive and effective technique for tumor ablation. Frequency and acoustic power are the most effective parameters for temperature distribution and the extent of tissue damage. The aim of this study was to optimize the operating transducer parameters such as frequency and input power in order to acquire suitable temperatu...
متن کاملTherapeutic effects of high intensity focused ultrasound for in patients with benign uterine tumors with regard to lifestyle and obstetric characteristics
Background: The present investigation compared the decrease in the volume of benign tumor before and after High Intensity Focused Ultrasound (HIFU) treatment to evaluate the therapeutic effects of HIFU. in terms of Lifestyle and obstetric characteristics of in patients with Benign Uterine Tumors. Materials and Methods: To collect the data on each patients’ lifestyle and obstetric characteristic...
متن کاملLaser-enhanced cavitation during high intensity focused ultrasound: An in vivo study.
Laser-enhanced cavitation during high intensity focused ultrasound (HIFU) was studied in vivo using a small animal model. Laser light was employed to illuminate the sample concurrently with HIFU radiation. The resulting cavitation was detected with a passive cavitation detector. The in vivo measurements were made under different combinations of HIFU treatment depths, laser wavelengths, and HIFU...
متن کاملCorrelation between Ultrasound Reflection Intensity and Tumor Ablation Ratio of Late-Stage Pancreatic Carcinoma in HIFU Therapy: Dynamic Observation on Ultrasound Reflection Intensity
The minimally invasive high-intensity focused ultrasound (HIFU) therapy is thermal ablation treatment for late-stage pancreatic carcinoma with widely recognized safety and effectiveness, but there are currently no instant assessment methods for its ablation effect. It is vital to find a real-time high-sensitive assessment method. This research aims to dynamically observe the variation rules of ...
متن کاملChanges in quantitative ultrasound parameters during HIFU application
Quantitative ultrasound (QUS) is a novel imaging technique that is hypothesized to be capable of monitoring of High Intensity Focused Ultrasound (HIFU) treatment by quantifying tissue changes during exposure. Experiments were conducted on fresh liver samples from rats and lesions were formed using a HIFU system (1-MHz, f/1.2). A wire thermocouple was inserted into the sample to monitor temperat...
متن کامل