AbstractID: 10123 Title: Effects of breathing variation on internal target volume (ITV) in respiratory gated radiation therapy
ثبت نشده
چکیده
ID: 10123 Title: Effects of breathing variation on internal target volume (ITV) in respiratory gated radiation therapy Introduction: Accuracy of 4DCT reconstruction depends on reproducible patient breathing during scans and highly synchronized external surrogates. Studies have been conducted to investigate the effects of breathing variation on the motion information extracted from 4DCT (1, 2). Our previous study showed that tumor ITV can be underestimated by 4DCT maximum intensity projection (MIP)-based measurement by up to 50% due to breathing variation (1). In respiratorygated radiation therapy, the planning target volume (PTV) is composed of the ITV in the gated window (ITVGW) and a setup margin (SM): PTVGW=ITVGW+SM. Similarly, due to the breathing variation of patients, ITVGW determined from 4DCT can also be erroneous. It is the objective of this study to investigate the effects of breathing variation on ITVGW in the respiratory gated radiation therapy. Methods and Materials: 7 healthy volunteers (mean age 39.8) and 5 lung cancer patients (mean age 68.4) were included in this study. All MR images were acquired on a 1.5T MRI scanner (Avanto, Siemens, Germany) using a TrueFISP sequence. A single sagittal plane, in the middle right lung for volunteers and across the center of the tumor for patients, was scanned for a continuous 5-minute for each subject. All subjects were instructed to breathe normally during the scan. Imaging parameters (TR/TE: 3.7/1.13 ms; FOV: 384×312 mm; Flip angle: 52°; Slice thickness: 7 mm; Matrix: 256×208) were used so that the acquisition rate (0.3 seconds per frame) is similar to that of 4DCT. Motion trajectories of tumor (for patients) or a pulmonary vessel (for volunteers) were determined from dMRI and used in 4DCT simulation. A MATLAB program was written to simulate cine-mode 4DCT acquisition by segmenting and rebinning the dynamic MR images. The simulation method has been described in details previously (1) and will not be repeated here. Phantom study: Image motion phantoms were created to mimic lung motion, with a solid disk to represent the “tumor” (1). The density of the “lung” and “tumor” was set to 0 and 1 respectively. The “tumor” was initially placed at the center of the image and then moved with given motion trajectories determined from dMRI. Dynamic phantom images generated in such manner were then used to reconstruct simulated 4DCT images (sCT). Subsequently a single-breathingcycle motion trajectory of the “tumor” is determined from the 10-bin sCT. An exhalation gating window was determined as the phases within which the residue motion of the “tumor” is less than 5 mm. If the gating window contains more than 5 phases, then only the 5 phases with the smallest residual motion were selected. sCT images in the gating window were then grouped to generate a MIP image, from which the gated window internal target area (ITAGW, 2D counterpart of ITVGW) was determined. Similarly, the 5-minute dynamic phantom images in the gating window were also grouped. Instead of a MIP image, an average intensity of projection (AIP) image was generated in this case, and ITAGW was determined as the area in the AIP image where the intensity is greater than 0.05. In another word, locations where the “tumor” presented less than 5% of its entire moving time were not included in ITAGW. This is to avoid potential errors induced by sudden breathing changes. Area (ITAGW), major axis (L1) and minor axis (L2) of the ITAGW were determined for each of the ITAGW, as shown in Fig. 1d. Measurements from sCT were compared with those from dMRI. In addition, Dice coefficient of similarity (DSC) between the two ITAGW was calculated. Our simulation method was validated with hypothesized 5-mintue sinusoidal trajectory (period=5s; amplitude=10mm). Ideally, results from sCT and dMRI should be the same in this case. Patient study: Similar study was preformed on the dynamic MR images of lung cancer patients. Exhalation gating window was determined in the same manner as described above. MIP images in the gating window were generated for both sCT and dMRI, from which the ITAGW was determined. Unlike in the phantom study, ITAGW were manually contoured by experienced oncologist in this case. Measurements of ITAGW, L1, L2 and DSC were also performed. Results: Phantom study with the sinusoidal trajectory showed identical measurements of ITAGW, L1, L2 between sCT and dRMI (not shown), with a DSC of 1. The results validated our simulation. Fig. 1 shows an example of the phantom study. Gating window of 20% to 60% was chosen based on the single-breathing-cycle trajectory determined from sCT (Fig. 1b). Gated window MIP images generated for sCT and dMRI are substantially different (Fig. 1c). Fig. 2 shows an example of the patient study. Gated window AIP images showed apparent difference between sCT and dMRI, as well as the ITAGW indicated by red arrows (Fig. 2b), primarily due to the large breathing variation of this patient (Fig. 2a). Over all, in the phantom study with 3cm ‘tumor’ (Fig. 3b), measurements in dMRI are significantly (p-value<0.001) greater than those in sCT (ITAGW=992.9±121.7mm, L1=38.1±3.8mm, L2=33.1±1.0mm in dMRI; ITAGW=836.7±66.6mm, L1=34.1±2.4mm, L2=31.2±0.7mm in sCT). These differences are even greater in the phantom study with 1cm ‘tumor’ as shown in Fig. 3a (ITAGW=189.9±44.7mm, L1=18.7±4.0mm, L2=13.0±0.7mm in dMRI; ITAGW=131.7±13.8mm, L1=15.0±1.5mm, L2=11.4±0.5mm in sCT). ITAGW similarity is 0.91±0.05 and 0.79±0.10 for the 3cm and 1cm “tumor” respectively. Similar results were found in the patients study (ITAGW=1554.4±822.5mm, L1=49.9±11.3mm, L2=38.5±11.9mm in dMRI; ITAGW=1319.0±852.7mm, L1=43.2±14.0mm, L2=36.8±12.0mm in sCT), with an ITAGW similarity of 0.83±0.09. In addition, these differences between sCT and dMRI are more substantial when lung motion range is larger than 1cm, as shown in Fig. 4, independent of the “tumor” size. Discussion: Our results showed that ITVGW can be underestimated by 4DCT, suggesting an additional margin to account for breathing variation may be necessary in defining PTVGW for respiratory-gated radiation therapy. Explicitly, we propose PTVGW=ITVGW+VM+SM, where VM is the breathing variation margin. If the margin can be approximated as (L1dMRI L1sCT)/2 and (L2dMRI – L2sCT)/2 in the two axis respectively, then the margin size is about 3 mm and 1 mm in the major axis and minor axis respectively. This margin is expected to be larger when tumor motion is greater than 1 cm. There are several AbstractID: 10123 Title: Effects of breathing variation on internal target volume (ITV) in respiratory gated radiation therapyID: 10123 Title: Effects of breathing variation on internal target volume (ITV) in respiratory gated radiation therapy limitations of this study, including potential simulation errors and over-simplified patient selection criteria for gated therapy. In addition, the dosimetry effects of breathing variation in the reparatory gated treatment require further investigation. Some respiratory gating systems (such as Varian’s RPM system) have self-correction algorithm to minimize the effects of breathing variation during the treatment. Irregular breathing can be automatically detected and radiation beam will be automatically turned off that period, which may diminish the dosimetry effects of breathing variation. Conclusion: Our simulation study demonstrated that 4DCT-based measurement may underestimate the gated window ITV in respiratory gated radiation therapy. An addition margin to account for the breathing variation may be necessary in determining the gated window PTV. References: 1. Cai J, et al. Estimation of the error in maximum intensity projection (MIP) based internal volume (ITV) of lung tumors: a simulation and comparison study based on dynamic MRI. Int J Radiat Oncol Biol Phys 2007;69:895-902. 2. Simon L, et al. Initial evaluation of a four-dimensional computed tomography system using a programmable motor. J Appl Clin Med Phys 2006;7:50-65. Figure 1: (a) Motion trajectory in the SI direction determined from dMRI and used to generate motion phantom images. (b) Singe-breathing-cycle trajectories determined from simulated 4DCT. Gating window is 20%-60% in this case. (c) Gated window ITAs determined from sCT and dMRI, and the difference between the two. (d) Sketches explaining the measurements of major axis, minor axis and similarity. Figure 2: (a) Motion trajectory in the SI direction determined from dMRI of a lung cancer patient. (b) Gated window MIP images showing the gated window ITAs determined from sCT and dMRI, indicated by red arrows.
منابع مشابه
Investigation of lung normal tissue doses in lung tumors radiation therapy using both gated and conventional radiotherapy
Introduction: In radiation therapy of lung tumors, respiratory motion causes target moving, so a larger margin is needed to cover the clinical target volume (CTV). With the margin increasing, a larger volume of normal tissue will be exposed to high-dose. In this study, dosimetric parameters of normal lung tissue were compared between gated and conventional radiotherapy (RT), u...
متن کاملInvestigation of tumor motion influence on applied dose distribution in conventional proton therapy vs. IMPT a 4D Monte Carlo simulation study
Background: in radiation treatment of moving targets located in thorax region of patient body, the delivered dose does not match with the planned treatment, resulting in some over and under dosage in the tumor volume, as a function of motion magnitude and frequency. Several efforts have been done to investigate the target motion effects on dose distribution in the target and surrounding normal ...
متن کامل2-[18F]Fluoro-2-Deoxy-D-Glucose Positron Emission Tomography Definition of Lung Targets in Vero Stereotactic Body Radiation Therapy Workflow
This retrospective study explored 2-[18F]fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET) as an aid in target delineation among a first-group of five patients with single or multiple moving lung tumors planned for Vero stereotactic body radiation therapy (SBRT). Computed tomography (CT)-based free-breathing, end-inspiration, and end-expiration lung target volumes generated a sing...
متن کاملTo gate or not to gate - dosimetric evaluation comparing Gated vs. ITV-based methodologies in stereotactic ablative body radiotherapy (SABR) treatment of lung cancer
BACKGROUND To compare retrospectively generated gated plans to conventional internal target volume (ITV)-based plans and to evaluate whether gated radiotherapy provides clinically relevant dosimetric improvements to organs-at-risk (OARs). METHODS Evaluation was performed of 150 stereotactic ablative radiotherapy treatment plans delivered to 128 early-stage (T1-T3 (<5 cm)) NSCLC patients. To g...
متن کاملPhase Impact Factor: A Novel Parameter for Determining Optimal CT Phase in 4D Radiation Therapy Treatment Planning for Mobile Lung Cancer
Due to respiratory motion, lung tumor can move up to several centimeters. If respiratory motion is not carefully considered during the radiation treatment planning, the highly conformal dose distribution with steep gradients could miss the target. To address this issue, the common strategy is to add a population-derived safety margin to the gross tumor volume (GTV). However, during a free breat...