Corrected formula for the calculation of the electrical heart axis.

نویسندگان

  • D Novosel
  • G Noll
  • T F Lüscher
چکیده

The calculation of the heart axis in the frontal plane can be performed with the combination of any two leads. The use of combination of bipolar (I, II, III) and unipolar leads (aVR, aVL and aVF) can produce wrong results. Calculation of the electrical axis from leads I and aVF without correction (sometimes used in ECG recorders): EA= Arctan (aVF/I) results in lower values (in our study: 34 4 , n = 48) as compared to the values obtained with formula that uses leads I and II: EA= Arctan ((2*II-I)/(Sqr(3)*I)) (axis = 33+/-7 degrees, n=48; p<0.005, paired t-test with Bonferroni correction) or with corrected formula which uses leads I and aVF: EA=+/-Arctan ((2*aVF)/(Sqr(3)*I)) (axis = 374 degrees, n=48; p<0.005, paired t-test with Bonferroni correction). The correction factor 2/Sqr(3) is required because the unipolar and bipolar leads have different strengths. Although the difference rarely reach clinical significance, our results suggests that the ECG recorders should be proofed on formulas used for the calculation of the electrical axis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New formula for Calculation of Cobalt-60 Percent Depth Dose

Introduction:  On  the  basis  of  percent  depth  dose  (PDD)  calculation,  the  application  of  dosimetry  in  radiotherapy  has  an  important  role  to  play  in  reducing  the  chance  of  tumor  recurrence. The aim of this study is to introduce a new formula for calculating the centeral axis  percent depth doses of Cobalt-60 beam.   Materials and Methods: In the present study, based on ...

متن کامل

Visual and Refractive Results of Cataract Surgery by Phacoemulsification Method in Patients with Keratoconus

Purpose: To examine the visual and refractive results of cataract surgery by phacoemulsification method in patients with keratoconus. Methods: In this retrospective study, the files of patients with keratoconus, who underwent phacoemulsification between 2008 and 2017, were evaluated. The intraocular lens power calculation formula was SRK/T. Post-operative visual and refractive results were anal...

متن کامل

Determination of the attenuation coefficient for megavoltage photons in the water phantom

Background: Attenuation coefficient (μ) plays an important role in calculations of treatment planning systems, as well as determination of dose distributions in external beam therapy, dosimetry, protection, phantom materials and industry. So, its exact measurement or calculation is very important. The aim of this study was to evaluate the μ in different points in the water phantom anal...

متن کامل

Assessment of Dose Calculation Accuracy of TiGRT Treatment Planning System for Physical Wedged fields in Radiotherapy

Introduction Wedge modifiers are commonly applied in external beam radiotherapy to change the dose distribution corresponding to the body contour and to obtain a uniform dose distribution within the target volume. Since the radiation dose delivered to the target must be within ±5% of the prescribed dose, accurate dose calculation by a treatment planning system (TPS) is important. The objective ...

متن کامل

Simplified [correction of Simlified] calculation of mean QRS vector (mean electrical axis of heart) of electrocardiogram.

In clinical practice assessment of the mean QRS axis (MQRSA) provides information related either with hypertrophy of the ventricles or conduction blocks. The method adopted by clinicians i.e. the inspection of the QRS voltage in six of the limb leads has inherent element of subjectivity of approximately 10degrees. Moreover, in certain condition, when there is ambiguity about differentiation of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Croatian medical journal

دوره 40 1  شماره 

صفحات  -

تاریخ انتشار 1999