Surface quality of femtosecond dissected posterior human corneal stroma investigated with atomic force microscopy.

نویسندگان

  • Marco Lombardo
  • Maria P De Santo
  • Giuseppe Lombardo
  • Domenico Schiano Lomoriello
  • Giovanni Desiderio
  • Pietro Ducoli
  • Riccardo Barberi
  • Sebastiano Serrao
چکیده

PURPOSE To investigate and compare the surface roughness and morphology of posterior stromal lenticules created with a femtosecond laser using various pulse energies to that obtained with a mechanical microkeratome. METHODS A 150 kHz femtosecond laser platform (IntraLase iFS; Abbott Medical Optics) was programmed to create an 8.5-mm-diameter posterior stromal lenticule in 12 human corneal tissues. Specimens were dissected using different pulse energies (1.00, 0.75, 0.65, and 0.50) and fixed 2 μm spot separations. Three additional posterior corneal lenticules were prepared using a mechanical microkeratome (Moria Evolution 3; Moria). After the procedure, each corneal tissue was examined by atomic force microscopy (Autoprobe CP; Veeco). RESULTS Femtosecond laser-treated tissues revealed similar morphological features, however, with significant differences in surface roughness in relation to the energy pulse used for lamellar dissection (P<0.001). The most regular stromal surface was achieved when using 0.50 μJ pulse energy; on the contrary, the roughest specimens were those dissected using 1.00 μJ pulse energy. No differences in surface roughness were measured between mechanically resected tissues and those treated using 0.50 μJ pulse energy (P>0.05). CONCLUSIONS Atomic force microscopy submicron analysis of femtosecond-dissected donor tissues provided quantitative demonstration of the relation between pulse energy and stromal surface roughness. Surface quality of posterior corneal lenticules, comparable with that provided by mechanical microkeratome, is significantly improved when setting pulse energy for lamellar dissection of 0.50-μJ and 2-μm spot separations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanics of the anterior human corneal tissue investigated with atomic force microscopy.

PURPOSE To investigate the biomechanics of the anterior human corneal stroma using atomic force microscopy (AFM). METHODS AFM measurements were performed in liquid on the anterior stroma of human corneas, after gently removing the epithelium, using an atomic force microscope in the force spectroscopy mode. Rectangular silicon cantilevers with tip radius of 10 nm and spring elastic constants o...

متن کامل

Distribution of Young's Modulus in Porcine Corneas after Riboflavin/UVA-Induced Collagen Cross-Linking as Measured by Atomic Force Microscopy

Riboflavin/UVA-induced corneal collagen cross-linking has become an effective clinical application to treat keratoconus and other ectatic disorders of the cornea. Its beneficial effects are attributed to a marked stiffening of the unphysiologically weak stroma. Previous studies located the stiffening effect predominantly within the anterior cornea. In this study, we present an atomic force micr...

متن کامل

Effect of corneal opacity on LASIK flap creation with the femtosecond laser.

Effect of Corneal Opacity on LASIK Flap Creation With the Femtosecond Laser To the Editor: I read the recent article by Tomita et al, which appeared in the January 2012 issue of the Journal of Refractive Surgery,1 and would like to offer some comments. Tomita et al, in their retrospective study, investigated the respective incidence of vertical gas breakthrough (VGB) for patients with corneal o...

متن کامل

Understanding of the Viscoelastic Response of the Human Corneal Stroma Induced by Riboflavin/UV-A Cross-Linking at the Nano Level

PURPOSE To investigate the viscoelastic changes of the human cornea induced by riboflavin/UV-A cross-linking using Atomic Force Microscopy (AFM) at the nano level. METHODS Seven eye bank donor corneas were investigated, after gently removing the epithelium, using a commercial AFM in the force spectroscopy mode. Silicon cantilevers with tip radius of 10 nm and spring elastic constants between ...

متن کامل

Analysis of corneal stroma organization with wavefront optimized nonlinear microscopy.

PURPOSE To investigate the organization of stromal collagen in healthy ex vivo corneas of different species from second harmonic generation (SHG) microscopy images. METHODS A custom backscattered nonlinear microscope has been used to study the corneal structure of different species: porcine, bovine, rabbit, rat, chicken, and humans. The instrument uses a femtosecond laser for illumination, a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cornea

دوره 31 12  شماره 

صفحات  -

تاریخ انتشار 2012