Statistical analysis of the stability of the standard curve for some Syva EMIT assays.

نویسندگان

  • G V Zvaigzne
  • D A Brogan
  • L H Bernstein
چکیده

Derivation of standard curves for the EMIT therapeutic drug monitoring system involves several mathematical algorithms, all of which can be rewritten in the form of a linear equation y = mx + b. We examined the stability of the standard curve in terms of slope and y-intercept for three drug assays (procainamide, gentamicin, and carbamazepine) by generating calibration curves intermittently for periods as long as 90 days. Controls at three concentrations were assayed after each calibration to validate the standard curves. On the basis of 98% confidence intervals, the slopes of standard curves for procainamide, gentamicin, and carbamazepine were stable for 89, 80, and 57 days, respectively. Control values generated from standard-curve manipulations (adjustments to the y-intercept) indicated consistent accuracy and precision throughout the entire study, as compared with control values determined after each calibration. The increased utility of the standard curve and reagents suggests that full recalibration on a regular basis is not always necessary.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Drug screening with EMIT reagents: a quantitative approach to quality control.

We investigated the precision, linearity, accuracy, and stability of quantitative results for five drugs of abuse [amphetamines, benzoylecgonine, opiates, phencyclidine, and the cannabinoid-tetrahydrocannabinol (THC)-9-acid metabolite], analyzed in control specimens by using EMIT d.a.u. reagents (Syva Co.) with a Monarch 2000 analyzer with a nonlinear interpolation curve-fitting algorithm. The ...

متن کامل

Stability of standard curves prepared for EMIT homogeneous enzyme immunoassay kits stored at room temperature after reconstitution.

We examined the stability of standard curves obtained with use of homogeneous enzyme immunoassay reagents (EMIT; Syva Corp., Palo Alto, CA) for assay of lidocaine, procainamide, N-acetylprocainamide, gentamicin, and theophylline, when stored at room temperature (23-24 degrees C) after reconstitution of the lyophilized materials. Standards were run and curves obtained for as long as 16 days afte...

متن کامل

An In - HouseOpiate EnzymoimmunoassayBased on the Syva EMIT # { 174 } Principle

Many laboratories involved in drug-abuse screening use enzymoimmunoassays such as Syva’s EMIT#{174} system. Although automation has been extensively used to reduce assay costs, further reductions can be achieved by the development of in-house reagents. We have developed our own reagents for the detection of opiates in urine by using the Syva EMIT principle and adapted it for use on an Eppendorf...

متن کامل

Stability analysis of stratified two-phase liquid-gas flow in a horizontal pipe

This study aimed at linear stability analysis of the stratified two-phase liquid-gas flow in a horizontal pipe. First, equations governing the linear stability of flow in each phase and boundary conditions were obtained. The governing equations were eigenvalue Orr Sommerfeld equations which are difficult and stiff problems to solve. After obtaining the velocity profiles of the gas and liquid ph...

متن کامل

Cost-effective assays for use in monitoring carbamazepine, phenobarbital, and phenytoin in serum.

Using Syva "EMIT" reagents and the Cobas Bio centrifugal analyzer, we have developed cost-effective assays for therapeutic drug monitoring of carbamazepine, phenobarbital, and phenytoin. With these optimized methods one can assay up to 2470 samples with a single 100-test EMIT kit with good precision and accuracy. Between-batch CVs, based on results of repeat analysis of routine patients' sample...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 32 3  شماره 

صفحات  -

تاریخ انتشار 1986